Gaining client pleasure is our company’s aim without end. We are going to make excellent efforts to create new and top-quality goods, meet your special requirements and provide you with pre-sale, on-sale and after-sale companies for Wholesale Price China Factory OEM ODM Type 3p 250A MCCB Symbol Electrical MCCB, Being a young escalating company, we might not the most effective, but we’re trying our greatest to generally be your fantastic partner.
Gaining client pleasure is our company’s aim without end. We are going to make excellent efforts to create new and top-quality goods, meet your special requirements and provide you with pre-sale, on-sale and after-sale companies for China MCCB and MCB, We take measure at any expense to achieve essentially the most up-to-date equipment and approaches. The packing of nominated brand is our a further distinguishing feature. The items to assure years of trouble-free service has attracted a great deal customers. The solutions are obtainable in improved designs and richer assortment, they’re created scientifically of purely raw supplies. It readily available in a variety of designs and specifications for your selection. The most recent kinds are a great deal better than the preceding one particular and they are quite popular with lots of prospects.
RDM5 series moulded case circuit breaker is applied to the circuit of AC 50HZ, insulation voltage 1000V, rated working voltage up to 690V, rated current up to 800A,which to distribute the power and protect the circuit and power source against overload , short-circuit and under voltage damage. Especially, when the current is lower 630A, it also can protect the motor. Normally breaker can infrequently invert and starting of motor. The product can be installed vertically and horizontally
1.Panel Modular Disassembly Design
2.Boxed accessory design,easy installation
3.Ultimate Breaking Ability
4.Compact Size
5.The rated short-circuit breaking current Ics is 10ka higher than the traditional product RDM1′s highest breaking capacity
6.RDM5 durable service lifeGaining client pleasure is our company’s aim without end. We are going to make excellent efforts to create new and top-quality goods, meet your special requirements and provide you with pre-sale, on-sale and after-sale companies for Wholesale Price China Factory OEM ODM Type 3p 250A MCCB Symbol Electrical MCCB, Being a young escalating company, we might not the most effective, but we’re trying our greatest to generally be your fantastic partner.
Wholesale Price China China MCCB and MCB, We take measure at any expense to achieve essentially the most up-to-date equipment and approaches. The packing of nominated brand is our a further distinguishing feature. The items to assure years of trouble-free service has attracted a great deal customers. The solutions are obtainable in improved designs and richer assortment, they’re created scientifically of purely raw supplies. It readily available in a variety of designs and specifications for your selection. The most recent kinds are a great deal better than the preceding one particular and they are quite popular with lots of prospects.
Paraphrase | ||
1 | Trademark | |
2 | Product model | |
3 | Technical Parameters | |
4 | Standard | |
5 | CCC Certification mark | |
6 | Company Name | |
7 | Handle | |
8 | Terminal screw | |
9 | Trip button | |
10 | Cover | |
11 | Middle cover | |
12 | Accessory mounting holes | |
13 | Base |
Upper
Casing
Middle
Piece
Lower
Casing
The product adopts double-layer insulationdesign to improve the safety of users.
· 6kA breaking capacity is needed during bidding and tendering,
4.5kA cannot meet the requirements of times any more
· All-series consistent 6kA breaking capacity, more excellent performance
· Meet the customers’ requirement for 50A and 63A breaking capacity
· Power consumption is far below the national standard requirement
63/100/125type
>Standard Cabinet: Greatsafety distance >Non-standard Cabinet: Saving oncabinet cost
The rated short-circuit breaking
current Ics is 10ka higher than the
traditional product RDM1′s highest
breakingcapacity, which effectively
improves the product
safetyperformance and meets the
high demand of customers.
Frame grade rated current l nm(A) | 63 | 125 | 160 | 250 | 400 | 630 | 800 | ||||||||||||||||||
Rated currentln(A) | 10、16、20、25、32、40、50、63 | 10、16、20、25、32、40、50、63、80、100、125 | 63、80、100、125、160 | 100、125、160、180、200、225、250 | 200、225、250、315、350、400 | 400、500、630 | 630、700、800 | ||||||||||||||||||
Pole(P) | 2、3、4 | 3、4/2、3、4/3、4 | 3、4/2、3、4 | 3、4/2、3、4/3、4 | 3、4 | ||||||||||||||||||||
Rated frequency(Hz) | 50 | ||||||||||||||||||||||||
Rated insulation voltageUi(V) | AC1000 | ||||||||||||||||||||||||
Rated impulse withstand voltage(V) | 12000 | ||||||||||||||||||||||||
Rated working voltageUe(V) | 400V | AC400/AC690 | |||||||||||||||||||||||
Arcing distance(mm) | ≤50 | ≤50 | ≤50 | ≤50 | ≤100 | ≤100 | ≤100 | ||||||||||||||||||
Short-circuit breaking capacity | L | M | S | L | M | H | S | L | M | S | L | M | H | L | M | H | S | L | M | H | L | M | H | ||
Rated Limit/Rated breaking capacity lcu/lcs(AC400V) | 25/15 | 35/25 | 25/18 | 50/35 | 70/50 | 100/70 | 25/18 | 35/23 | 50/35 | 25/18 | 50/35 | 70/50 | 100/70 | 50/50 | 70/70 | 100/75 | 50/35 | 50/50 | 70/70 | 100/75 | 65/65 | 75/75 | 100/75 | ||
Rated Limit/Rated breaking capacity lcu/lcs(AC690V) | / | / | / | 20/10. | 20/12. | 30/15. | / | 10/5. | 15/8. | / | 20/10. | 20/12. | 30/15 | 20/10. | 25/15 | 35/18 | / | 20/10. | 25/15 | 35/18 | 20/10. | 25/15 | 35/20 | ||
Use category | A | ||||||||||||||||||||||||
Standards compliant | IEC60947-2 GB/T14048-2 | ||||||||||||||||||||||||
Suitable for working environment temperature | -5℃+40℃ | ||||||||||||||||||||||||
Electrical life(times) | 8000 | 7500 | |||||||||||||||||||||||
Mechanical life(times) | 20000 | 20000 | 20000 | 20000 | 10000 | 10000 | 10000 | ||||||||||||||||||
Shunt release | ■ | ■ | ■ | ■ | ■ | ■ | ■ | ||||||||||||||||||
Undervoltage release | ■ | ■ | ■ | ■ | ■ | ■ | ■ | ||||||||||||||||||
Alarm contact | ■ | ■ | ■ | ■ | ■ | ■ | ■ | ||||||||||||||||||
Auxiliary contact | ■ | ■ | ■ | ■ | ■ | ■ | ■ |
2 poles 3 poles
4 poles Side
Product model | Pole | Front panel wiring | Installation size | Button position | ||||||||||||||||||
L1 | L2 | L3 | L4 | L5 | L6 | W1 | W2 | W3 | H1 | H2 | H3 | H4 | H5 | H6 | K | a | b | d | L7 | L8 | ||
RDM5-63L/M RDM5-125S/L |
2 | 130.0 | - | 116.5 | 85.0 | - | 49.5 | 50.0 | 11.0 | 25.0 | 83.0 | 71.0 | - | 57.0 | 24.5 | 24.5 | 18.5 | - | 111.0 | 3.5 | 17.0 | 20.0 |
3 | 130.0 | - | 116.5 | 85.0 | - | 49.5 | 75.0 | 11.0 | 50.0 | 83.0 | 71.0 | - | 57.0 | 24.5 | 24.5 | 18.5 | 25.0 | 111.0 | 3.5 | 16.5 | 20.0 | |
4 | 130.0 | - | 116.5 | 85.0 | - | 49.5 | 100.0 | 11.0 | 75.0 | 83.0 | 71.0 | - | 57.0 | 24.5 | 24.5 | 18.5 | 50.0 | 111.0 | 3.5 | 16.5 | 20.0 | |
RDM5-125M/H | 2 | 152.0 | - | 132.0 | 88.0 | 31.0 | 52.0 | 62 | 14.5 | 30.0 | 109.5 | 96.0 | - | 82.0 | 28.5 | 28.5 | 18.0 | - | 129.0 | 4.5 | - | 6.5 |
3 | 152.0 | - | 132.0 | 88.0 | 31.0 | 52.0 | 92 | 14.5 | 60.0 | 110.0 | 96.0 | - | 82.0 | 28.5 | 28.5 | 18.0 | 30.0 | 129.0 | 4.5 | 22.0 | 15.5 | |
4 | 152.0 | - | 132.0 | 88.0 | 31.0 | 65.0 | 122.0 | 14.5 | 90.0 | 110.0 | 96.0 | - | 82.0 | 28.5 | 28.5 | 18.0 | 60.0 | 129.0 | 4.5 | 22.0 | 16.5 | |
RDM5-160S/L/M | 2 | 150.0 | - | 133.0 | 88.0 | 31.0 | 52.0 | 62 | 14.5 | 30.0 | 93.0 | 79.0 | - | 65.0 | 23.5 | 23.5 | 22.0 | - | 129.0 | 3.5 | - | 16.5 |
3 | 150.0 | - | 133.0 | 88.0 | 31.0 | 52.0 | 92 | 14.5 | 60.0 | 93.0 | 79.0 | - | 65.0 | 23.5 | 23.5 | 22.0 | 30.0 | 129.0 | 3.5 | 22.0 | 15.5 | |
4 | 150.0 | - | 133.0 | 88.0 | 31.0 | 52.0 | 122.0 | 14.5 | 90.0 | 93.0 | 79.0 | - | 65.0 | 23.5 | 23.5 | 22.0 | 60.0 | 129.0 | 3.5 | 22.0 | 16.5 | |
RDM5-250S/L | 2 | 165.0 | - | 145.5 | 102.0 | 33.0 | 53.0 | 75.0 | 14.0 | 35.0 | 96.0 | 76.0 | - | 67.0 | 23 | 23.0 | 25.0 | - | 126.0 | 4.5 | 2.5 | 15.5 |
3 | 165.0 | - | 145.5 | 102.0 | 33.0 | 53.0 | 107.0 | 14.0 | 70.0 | 96.0 | 76.0 | - | 67.0 | 23 | 23.0 | 25.0 | 35.0 | 126.0 | 4.5 | 42.5 | 5.5 | |
4 | 165.0 | - | 145.5 | 102.0 | 33.0 | 53.0 | 142.0 | 14.0 | 105.0 | 96.0 | 76.0 | - | 67.0 | 23 | 23.0 | 25.0 | 70.0 | 126.0 | 4.5 | 43.0 | 15.5 | |
RDM5-250M/H | 2 | 165.0 | - | 145.0 | 102.0 | 53.0 | 53.0 | 75.0 | 14.0 | 55.0 | 112.5 | 94.0 | - | 85.0 | 22 | 22.0 | 24.0 | - | 126.0 | 4.5 | 2.5 | 15.5 |
3 | 165.0 | - | 145.0 | 102.0 | 33.0 | 53.0 | 107.0 | 14.0 | 70.0 | 115.0 | 94.0 | - | 85.0 | 23 | 23.0 | 23.0 | 35.0 | 126.0 | 4.5 | 42.5 | 15.5 | |
4 | 165.0 | - | 145.0 | 102.0 | 33.0 | 53.0 | 142.0 | 14.0 | 105.0 | 115.0 | 94.0 | - | 85.0 | 23 | 23.0 | 23.0 | 70.0 | 126.0 | 4.5 | 43.0 | 15.0 | |
RDM5-400L/M/H RDM5-630S |
3 | 258.0 | 178.0 | 224.0 | 132.0 | 53.0 | 100.0 | 150.0 | 35.0 | 96.0 | 152.0 | 115.0 | 101.0 | 99.0 | 38 | 38.0 | 31.0 | 44.0 | 194.0 | 7.0 | 57.5 | 30.0 |
4 | 258.0 | 179.0 | 224.0 | 132.0 | 53.0 | 100.0 | 198.0 | 35.0 | 144.0 | 152.0 | 115.0 | 101.0 | 99.0 | 38 | 38.0 | 31.0 | 94.0 | 194.0 | 7.0 | 57.5 | 30.0 | |
RDM5-630L/M/H | 3 | 270.0 | 185.0 | 235.5 | 146.0 | 52.5 | 100.0 | 182.0 | 35.5 | 116.0 | 158.0 | 119.0 | 106.0 | 103.0 | 45 | 43.0 | 41.0 | 58.0 | 200.0 | 7.0 | 58.0 | 32.0 |
4 | 270.0 | 185.0 | 235.5 | 146.0 | 52.5 | 100.0 | 240.0 | 35.5 | 174.0 | 158.0 | 119.0 | 106.0 | 103.0 | 45 | 43.0 | 41.0 | 116.0 | 200.0 | 7.0 | 58.0 | 31.5 | |
RDM5-800L/M/H | 3 | 280.0 | 205.0 | 243.0 | 148.0 | 52.0 | 100.0 | 210.0 | 35.0 | 140.0 | 159.0 | 122.0 | 109.0 | 105.0 | 40.5 | 42.5 | 45.0 | 70.0 | 243.0 | 7.0 | 53.0 | 24.5 |
4 | 280.0 | 205.0 | 243.0 | 148.0 | 52.0 | 100.0 | 280.0 | 35.0 | 210.0 | 159.0 | 122.0 | 109.0 | 105.0 | 40.5 | 42.5 | 45.0 | 140.0 | 243.0 | 7.0 | 53.0 | 24.5 |
Size code | ||||
(L11) | W3 | L9 | L10 | |
RDM5-63L M RDM5-125S、L |
64 | 19 | 14 | 43 |
RDM5-125M H RDM5-160S、L M |
- | 23 | 24 | 40 |
RDM5-250S.L.M.H | - | 23 | 30 | 44 |
RDM5-400L、M、H RDM5-630S |
- | 47 | 39 | 66 |
RDM5-630L、M、H | - | 47 | 39 | 66 |
RDM5-800L、M、H | - | 47 | 42 | 66 |
RDM5 series rear panel wiring installation panel opening size
3 Poles 4 Poles
RDM5 series rear panel wiring appearance and installation dimensions
RDM5- 125M/H 160、250 RDM5-400、630、800
RDM5-125~800 rear wiring appearance and mounting plate opening size
Product model | Size code | |||||||||
H3 | H4 | D | W | L2 | d2 | A | B | C | d1 | |
RDM5-125M H | 64 | 100 | M8 | 50 | 132 | 24 | 30 | 108 | 60 | 5.5 |
RDM5-160L.M | ||||||||||
RDM5-250L、M、H | 70 | 100 | M10 | 35 | 145 | 15 | 35 | 126 | 70 | 5.5 |
RDM5-400L.M、H RDM5-630S |
71 | 105.5 | - | 48 | 2242 | 32 | 44 | 194 | 94 | 7 |
RDM5-630L.M、H | 46 | 105 | - | 58 | 2346 | 37 | 58 | 200 | 116 | 7 |
RDM5-800L,M.H | 105 | 105 | - | 70 | 2436 | 48 | 70 | 243 | 70 | 7.5 |
RDM5 series plug-in front panel dimensions
Flat mount
Dimensions of RDM5-125~800 plug-in front panel circuit breaker
Product model | Size code | |||||||||||||
A | G | K | H | H | ₂ | Hs | L1 | L2 | AM | BM | ||||
RDM5-125M H | 172 | 95 | 38.5 | 50.5 | 35 | 16.5 | 61 | 185 | 217 | M6 | M8 | |||
RDM5-160L,M | ||||||||||||||
RDM5-250L,M、H | 183 | 95 | 44 | 52 | 35 | 18 | 65 | 230 | 259 | M6 | M10 | |||
RDM5-400L,M,H RDM5-630S |
276 | 170 | 53 | 79.5 | 67 | 18 | - | 322 | 352 | M6 | M10 | |||
RDM5-630L,M、H | 299 | 163.5 | 67.5 | 84.5 | 65.5 | 20 | - | 368 | 397 | M8 | M12 | |||
RDM5-80OL,M,H | 303 | 179 | 62 | 87.5 | 60.5 | 28 | 118 | 375 | 405 | M10 | M12 |
Hole size of the plug-in front wiring mounting plate (X-XY-Y is the center of the circuit breaker)
Beam installation Flat mount
RDM5-125~800 plug-in front wiring mounting plate opening size
Product model | RDM5-125M.H RDM5-160L.M |
RDM5-250L.M,H | RDM5-400L,M,H RDM5-630S |
RDM5-630L,M,H | RDM5-800L,M.H | |||||||||
pole | 3 | 3 | 3 | 3 | 3 | |||||||||
Mounting plate opening size(mm) | B | 66 | 70 | 115 | 90.5 | 90.5 | ||||||||
B1 | 50 | 60 | - | - | 65 | |||||||||
C | 60 | 64 | 135 | 144.5 | 144.5 | |||||||||
C1 | 35 | 35 | - | - | 80 | |||||||||
d | 6.5 | 6.5 | 6.5 | 8.5 | 11 |
RDM5 series plug-in panel rear dimensions and mounting panel opening dimensions
Dimensions of RDM5-125~800 plug-in rear panel circuit breaker
Product model | Size code | ||||||||||
A | F | G | K | H | H1 | H2 | H3 | H4 | AM | BM | |
RDM5-125M H RDM5-160L M |
168 | 133 | 92 | 38 | 48 | 32.5 | 32.5 | 18 | 17 | M6 | M8 |
RDM5-25OL、M、H | 186 | 144 | 95 | 45.5 | 49.5 | 33.5 | 34 | 15 | 17 | M6 | M8 |
RDM5-400L、M、H RDM5-630S |
280 | 224 | 171 | 54.5 | 59.5 | 40 | 44 | 23.5 | 20 | M8 | M12 |
RDM5-630L、M、H | 300 | 234 | 170 | 65 | 59 | 40 | 50 | 30 | 20 | M8 | M12 |
RDM5-800L、M、H | 305 | 243 | 181 | 62 | 87 | 60 | - | - | 28 | M10 | M14 |
Hole size of plug-in rear wiring installation panel (X-XY-Y is the center of the circuit breaker)
RDM5-125~800 plug-in rear wiring installation panel opening size
Product model | RDM5-125M.H RDMS-160L.M |
RDM5-25OL,M,H | RDM5-400L、M、H RDM5-630S |
RDM5-630L M.H | RDM5-80OL. M.H | |||||||
pole | 3 | 4 | 3 | 4 | 3 | 4 | 3 | 4 | 3 | 4 | ||
Mounting plate opening size(mm) | A | 91 | - | 107 | - | 149 | - | 182 | - | 210 | - | |
A1 | - | 129 | - | 145 | - | 200 | - | 242 | - | 290 | ||
B | 60 | - | 70 | - | 60 | - | 100 | - | 90 | - | ||
B1 | - | 90 | - | 105 | - | 108 | - | 158 | - | 162 | ||
C | 56 | 54 | 129 | 123 | 146 | |||||||
D | 38 | 45.5 | 54.5 | 65 | 62 | |||||||
E | 92 | 95 | 171 | 170 | 181 | |||||||
d | 6.5 | 6.5 | 8.5 | 8.5 | 11 |
Paraphrase | ||
1 | Trademark | |
2 | Product model | |
3 | Technical Parameters | |
4 | Standard | |
5 | CCC Certification mark | |
6 | Company Name | |
7 | Handle | |
8 | Terminal screw | |
9 | Trip button | |
10 | Cover | |
11 | Middle cover | |
12 | Accessory mounting holes | |
13 | Base |
Upper
Casing
Middle
Piece
Lower
Casing
The product adopts double-layer insulationdesign to improve the safety of users.
· 6kA breaking capacity is needed during bidding and tendering,
4.5kA cannot meet the requirements of times any more
· All-series consistent 6kA breaking capacity, more excellent performance
· Meet the customers’ requirement for 50A and 63A breaking capacity
· Power consumption is far below the national standard requirement
63/100/125type
>Standard Cabinet: Greatsafety distance >Non-standard Cabinet: Saving oncabinet cost
The rated short-circuit breaking
current Ics is 10ka higher than the
traditional product RDM1′s highest
breakingcapacity, which effectively
improves the product
safetyperformance and meets the
high demand of customers.
Frame grade rated current l nm(A) | 63 | 125 | 160 | 250 | 400 | 630 | 800 | ||||||||||||||||||
Rated currentln(A) | 10、16、20、25、32、40、50、63 | 10、16、20、25、32、40、50、63、80、100、125 | 63、80、100、125、160 | 100、125、160、180、200、225、250 | 200、225、250、315、350、400 | 400、500、630 | 630、700、800 | ||||||||||||||||||
Pole(P) | 2、3、4 | 3、4/2、3、4/3、4 | 3、4/2、3、4 | 3、4/2、3、4/3、4 | 3、4 | ||||||||||||||||||||
Rated frequency(Hz) | 50 | ||||||||||||||||||||||||
Rated insulation voltageUi(V) | AC1000 | ||||||||||||||||||||||||
Rated impulse withstand voltage(V) | 12000 | ||||||||||||||||||||||||
Rated working voltageUe(V) | 400V | AC400/AC690 | |||||||||||||||||||||||
Arcing distance(mm) | ≤50 | ≤50 | ≤50 | ≤50 | ≤100 | ≤100 | ≤100 | ||||||||||||||||||
Short-circuit breaking capacity | L | M | S | L | M | H | S | L | M | S | L | M | H | L | M | H | S | L | M | H | L | M | H | ||
Rated Limit/Rated breaking capacity lcu/lcs(AC400V) | 25/15 | 35/25 | 25/18 | 50/35 | 70/50 | 100/70 | 25/18 | 35/23 | 50/35 | 25/18 | 50/35 | 70/50 | 100/70 | 50/50 | 70/70 | 100/75 | 50/35 | 50/50 | 70/70 | 100/75 | 65/65 | 75/75 | 100/75 | ||
Rated Limit/Rated breaking capacity lcu/lcs(AC690V) | / | / | / | 20/10. | 20/12. | 30/15. | / | 10/5. | 15/8. | / | 20/10. | 20/12. | 30/15 | 20/10. | 25/15 | 35/18 | / | 20/10. | 25/15 | 35/18 | 20/10. | 25/15 | 35/20 | ||
Use category | A | ||||||||||||||||||||||||
Standards compliant | IEC60947-2 GB/T14048-2 | ||||||||||||||||||||||||
Suitable for working environment temperature | -5℃+40℃ | ||||||||||||||||||||||||
Electrical life(times) | 8000 | 7500 | |||||||||||||||||||||||
Mechanical life(times) | 20000 | 20000 | 20000 | 20000 | 10000 | 10000 | 10000 | ||||||||||||||||||
Shunt release | ■ | ■ | ■ | ■ | ■ | ■ | ■ | ||||||||||||||||||
Undervoltage release | ■ | ■ | ■ | ■ | ■ | ■ | ■ | ||||||||||||||||||
Alarm contact | ■ | ■ | ■ | ■ | ■ | ■ | ■ | ||||||||||||||||||
Auxiliary contact | ■ | ■ | ■ | ■ | ■ | ■ | ■ |
2 poles 3 poles
4 poles Side
Product model | Pole | Front panel wiring | Installation size | Button position | ||||||||||||||||||
L1 | L2 | L3 | L4 | L5 | L6 | W1 | W2 | W3 | H1 | H2 | H3 | H4 | H5 | H6 | K | a | b | d | L7 | L8 | ||
RDM5-63L/M RDM5-125S/L |
2 | 130.0 | - | 116.5 | 85.0 | - | 49.5 | 50.0 | 11.0 | 25.0 | 83.0 | 71.0 | - | 57.0 | 24.5 | 24.5 | 18.5 | - | 111.0 | 3.5 | 17.0 | 20.0 |
3 | 130.0 | - | 116.5 | 85.0 | - | 49.5 | 75.0 | 11.0 | 50.0 | 83.0 | 71.0 | - | 57.0 | 24.5 | 24.5 | 18.5 | 25.0 | 111.0 | 3.5 | 16.5 | 20.0 | |
4 | 130.0 | - | 116.5 | 85.0 | - | 49.5 | 100.0 | 11.0 | 75.0 | 83.0 | 71.0 | - | 57.0 | 24.5 | 24.5 | 18.5 | 50.0 | 111.0 | 3.5 | 16.5 | 20.0 | |
RDM5-125M/H | 2 | 152.0 | - | 132.0 | 88.0 | 31.0 | 52.0 | 62 | 14.5 | 30.0 | 109.5 | 96.0 | - | 82.0 | 28.5 | 28.5 | 18.0 | - | 129.0 | 4.5 | - | 6.5 |
3 | 152.0 | - | 132.0 | 88.0 | 31.0 | 52.0 | 92 | 14.5 | 60.0 | 110.0 | 96.0 | - | 82.0 | 28.5 | 28.5 | 18.0 | 30.0 | 129.0 | 4.5 | 22.0 | 15.5 | |
4 | 152.0 | - | 132.0 | 88.0 | 31.0 | 65.0 | 122.0 | 14.5 | 90.0 | 110.0 | 96.0 | - | 82.0 | 28.5 | 28.5 | 18.0 | 60.0 | 129.0 | 4.5 | 22.0 | 16.5 | |
RDM5-160S/L/M | 2 | 150.0 | - | 133.0 | 88.0 | 31.0 | 52.0 | 62 | 14.5 | 30.0 | 93.0 | 79.0 | - | 65.0 | 23.5 | 23.5 | 22.0 | - | 129.0 | 3.5 | - | 16.5 |
3 | 150.0 | - | 133.0 | 88.0 | 31.0 | 52.0 | 92 | 14.5 | 60.0 | 93.0 | 79.0 | - | 65.0 | 23.5 | 23.5 | 22.0 | 30.0 | 129.0 | 3.5 | 22.0 | 15.5 | |
4 | 150.0 | - | 133.0 | 88.0 | 31.0 | 52.0 | 122.0 | 14.5 | 90.0 | 93.0 | 79.0 | - | 65.0 | 23.5 | 23.5 | 22.0 | 60.0 | 129.0 | 3.5 | 22.0 | 16.5 | |
RDM5-250S/L | 2 | 165.0 | - | 145.5 | 102.0 | 33.0 | 53.0 | 75.0 | 14.0 | 35.0 | 96.0 | 76.0 | - | 67.0 | 23 | 23.0 | 25.0 | - | 126.0 | 4.5 | 2.5 | 15.5 |
3 | 165.0 | - | 145.5 | 102.0 | 33.0 | 53.0 | 107.0 | 14.0 | 70.0 | 96.0 | 76.0 | - | 67.0 | 23 | 23.0 | 25.0 | 35.0 | 126.0 | 4.5 | 42.5 | 5.5 | |
4 | 165.0 | - | 145.5 | 102.0 | 33.0 | 53.0 | 142.0 | 14.0 | 105.0 | 96.0 | 76.0 | - | 67.0 | 23 | 23.0 | 25.0 | 70.0 | 126.0 | 4.5 | 43.0 | 15.5 | |
RDM5-250M/H | 2 | 165.0 | - | 145.0 | 102.0 | 53.0 | 53.0 | 75.0 | 14.0 | 55.0 | 112.5 | 94.0 | - | 85.0 | 22 | 22.0 | 24.0 | - | 126.0 | 4.5 | 2.5 | 15.5 |
3 | 165.0 | - | 145.0 | 102.0 | 33.0 | 53.0 | 107.0 | 14.0 | 70.0 | 115.0 | 94.0 | - | 85.0 | 23 | 23.0 | 23.0 | 35.0 | 126.0 | 4.5 | 42.5 | 15.5 | |
4 | 165.0 | - | 145.0 | 102.0 | 33.0 | 53.0 | 142.0 | 14.0 | 105.0 | 115.0 | 94.0 | - | 85.0 | 23 | 23.0 | 23.0 | 70.0 | 126.0 | 4.5 | 43.0 | 15.0 | |
RDM5-400L/M/H RDM5-630S |
3 | 258.0 | 178.0 | 224.0 | 132.0 | 53.0 | 100.0 | 150.0 | 35.0 | 96.0 | 152.0 | 115.0 | 101.0 | 99.0 | 38 | 38.0 | 31.0 | 44.0 | 194.0 | 7.0 | 57.5 | 30.0 |
4 | 258.0 | 179.0 | 224.0 | 132.0 | 53.0 | 100.0 | 198.0 | 35.0 | 144.0 | 152.0 | 115.0 | 101.0 | 99.0 | 38 | 38.0 | 31.0 | 94.0 | 194.0 | 7.0 | 57.5 | 30.0 | |
RDM5-630L/M/H | 3 | 270.0 | 185.0 | 235.5 | 146.0 | 52.5 | 100.0 | 182.0 | 35.5 | 116.0 | 158.0 | 119.0 | 106.0 | 103.0 | 45 | 43.0 | 41.0 | 58.0 | 200.0 | 7.0 | 58.0 | 32.0 |
4 | 270.0 | 185.0 | 235.5 | 146.0 | 52.5 | 100.0 | 240.0 | 35.5 | 174.0 | 158.0 | 119.0 | 106.0 | 103.0 | 45 | 43.0 | 41.0 | 116.0 | 200.0 | 7.0 | 58.0 | 31.5 | |
RDM5-800L/M/H | 3 | 280.0 | 205.0 | 243.0 | 148.0 | 52.0 | 100.0 | 210.0 | 35.0 | 140.0 | 159.0 | 122.0 | 109.0 | 105.0 | 40.5 | 42.5 | 45.0 | 70.0 | 243.0 | 7.0 | 53.0 | 24.5 |
4 | 280.0 | 205.0 | 243.0 | 148.0 | 52.0 | 100.0 | 280.0 | 35.0 | 210.0 | 159.0 | 122.0 | 109.0 | 105.0 | 40.5 | 42.5 | 45.0 | 140.0 | 243.0 | 7.0 | 53.0 | 24.5 |
Size code | ||||
(L11) | W3 | L9 | L10 | |
RDM5-63L M RDM5-125S、L |
64 | 19 | 14 | 43 |
RDM5-125M H RDM5-160S、L M |
- | 23 | 24 | 40 |
RDM5-250S.L.M.H | - | 23 | 30 | 44 |
RDM5-400L、M、H RDM5-630S |
- | 47 | 39 | 66 |
RDM5-630L、M、H | - | 47 | 39 | 66 |
RDM5-800L、M、H | - | 47 | 42 | 66 |
RDM5 series rear panel wiring installation panel opening size
3 Poles 4 Poles
RDM5 series rear panel wiring appearance and installation dimensions
RDM5- 125M/H 160、250 RDM5-400、630、800
RDM5-125~800 rear wiring appearance and mounting plate opening size
Product model | Size code | |||||||||
H3 | H4 | D | W | L2 | d2 | A | B | C | d1 | |
RDM5-125M H | 64 | 100 | M8 | 50 | 132 | 24 | 30 | 108 | 60 | 5.5 |
RDM5-160L.M | ||||||||||
RDM5-250L、M、H | 70 | 100 | M10 | 35 | 145 | 15 | 35 | 126 | 70 | 5.5 |
RDM5-400L.M、H RDM5-630S |
71 | 105.5 | - | 48 | 2242 | 32 | 44 | 194 | 94 | 7 |
RDM5-630L.M、H | 46 | 105 | - | 58 | 2346 | 37 | 58 | 200 | 116 | 7 |
RDM5-800L,M.H | 105 | 105 | - | 70 | 2436 | 48 | 70 | 243 | 70 | 7.5 |
RDM5 series plug-in front panel dimensions
Flat mount
Dimensions of RDM5-125~800 plug-in front panel circuit breaker
Product model | Size code | |||||||||||||
A | G | K | H | H | ₂ | Hs | L1 | L2 | AM | BM | ||||
RDM5-125M H | 172 | 95 | 38.5 | 50.5 | 35 | 16.5 | 61 | 185 | 217 | M6 | M8 | |||
RDM5-160L,M | ||||||||||||||
RDM5-250L,M、H | 183 | 95 | 44 | 52 | 35 | 18 | 65 | 230 | 259 | M6 | M10 | |||
RDM5-400L,M,H RDM5-630S |
276 | 170 | 53 | 79.5 | 67 | 18 | - | 322 | 352 | M6 | M10 | |||
RDM5-630L,M、H | 299 | 163.5 | 67.5 | 84.5 | 65.5 | 20 | - | 368 | 397 | M8 | M12 | |||
RDM5-80OL,M,H | 303 | 179 | 62 | 87.5 | 60.5 | 28 | 118 | 375 | 405 | M10 | M12 |
Hole size of the plug-in front wiring mounting plate (X-XY-Y is the center of the circuit breaker)
Beam installation Flat mount
RDM5-125~800 plug-in front wiring mounting plate opening size
Product model | RDM5-125M.H RDM5-160L.M |
RDM5-250L.M,H | RDM5-400L,M,H RDM5-630S |
RDM5-630L,M,H | RDM5-800L,M.H | |||||||||
pole | 3 | 3 | 3 | 3 | 3 | |||||||||
Mounting plate opening size(mm) | B | 66 | 70 | 115 | 90.5 | 90.5 | ||||||||
B1 | 50 | 60 | - | - | 65 | |||||||||
C | 60 | 64 | 135 | 144.5 | 144.5 | |||||||||
C1 | 35 | 35 | - | - | 80 | |||||||||
d | 6.5 | 6.5 | 6.5 | 8.5 | 11 |
RDM5 series plug-in panel rear dimensions and mounting panel opening dimensions
Dimensions of RDM5-125~800 plug-in rear panel circuit breaker
Product model | Size code | ||||||||||
A | F | G | K | H | H1 | H2 | H3 | H4 | AM | BM | |
RDM5-125M H RDM5-160L M |
168 | 133 | 92 | 38 | 48 | 32.5 | 32.5 | 18 | 17 | M6 | M8 |
RDM5-25OL、M、H | 186 | 144 | 95 | 45.5 | 49.5 | 33.5 | 34 | 15 | 17 | M6 | M8 |
RDM5-400L、M、H RDM5-630S |
280 | 224 | 171 | 54.5 | 59.5 | 40 | 44 | 23.5 | 20 | M8 | M12 |
RDM5-630L、M、H | 300 | 234 | 170 | 65 | 59 | 40 | 50 | 30 | 20 | M8 | M12 |
RDM5-800L、M、H | 305 | 243 | 181 | 62 | 87 | 60 | - | - | 28 | M10 | M14 |
Hole size of plug-in rear wiring installation panel (X-XY-Y is the center of the circuit breaker)
RDM5-125~800 plug-in rear wiring installation panel opening size
Product model | RDM5-125M.H RDMS-160L.M |
RDM5-25OL,M,H | RDM5-400L、M、H RDM5-630S |
RDM5-630L M.H | RDM5-80OL. M.H | |||||||
pole | 3 | 4 | 3 | 4 | 3 | 4 | 3 | 4 | 3 | 4 | ||
Mounting plate opening size(mm) | A | 91 | - | 107 | - | 149 | - | 182 | - | 210 | - | |
A1 | - | 129 | - | 145 | - | 200 | - | 242 | - | 290 | ||
B | 60 | - | 70 | - | 60 | - | 100 | - | 90 | - | ||
B1 | - | 90 | - | 105 | - | 108 | - | 158 | - | 162 | ||
C | 56 | 54 | 129 | 123 | 146 | |||||||
D | 38 | 45.5 | 54.5 | 65 | 62 | |||||||
E | 92 | 95 | 171 | 170 | 181 | |||||||