Fast and great quotations, informed advisers to help you choose the correct product that suits all your preferences, a short manufacturing time, responsible excellent handle and distinctive services for paying and shipping affairs for Rapid Delivery for High Quality 800A 3poles Air Circuit Breaker Acb, We normally welcome new and old buyers offers us with beneficial tips and proposals for cooperation, let us mature and produce alongside one another, also to lead to our neighborhood and employees!
Fast and great quotations, informed advisers to help you choose the correct product that suits all your preferences, a short manufacturing time, responsible excellent handle and distinctive services for paying and shipping affairs for China Intelligent Circuit Breaker and Air Circuit Breaker Acb Factory, We adhere to client 1st, top quality 1st, continuous improvement, mutual advantage and win-win principles. When cooperation together with the customer, we deliver shoppers with the highest high-quality of service. Established good business relations using the Zimbabwe buyer inside the business, we’ve got established own brand and reputation. At the identical time, wholeheartedly welcome new and old prospects to our company to go to and negotiate small business.
RDW5 series intelligent type Air circuit breaker is applied to power distribution network of AC 50/60Hz, rated operating voltage up to 400V/690V, rated current up to 6300A. It’s mainly used to distribute power and protect circuit and power-supply equipment against damage of faults, such as overload, under-voltage, short-circuit, single-phase grounding, and it has insulation function. Besides, the circuit breaker has various intelligent protect function, can realize bidirectional communication between several breaker and central control computer by its network system, realize remote control function to satisfied the requirements of automatic system control. The circuit breaker conforms the standard of IEC60947-2.
1.ECONOMICAL & FLEXIBLE
2.Quality Parts, Durability, Modular Design, Safe & Reliable
3.HIGHER electrical lifespan
4.More durable & Better performance
5.reduced maintenance cost
6.Innovaive ARC Extinguishing Design
7.Creating“CORE”design “WISDOM”for future
8.Compact in Size
9.Unique Secondary Terminal
10.Flexible Connection
11.Stringent environment capabilitiesFast and great quotations, informed advisers to help you choose the correct product that suits all your preferences, a short manufacturing time, responsible excellent handle and distinctive services for paying and shipping affairs for Rapid Delivery for High Quality 800A 3poles Air Circuit Breaker Acb, We normally welcome new and old buyers offers us with beneficial tips and proposals for cooperation, let us mature and produce alongside one another, also to lead to our neighborhood and employees!
Rapid Delivery for China Intelligent Circuit Breaker and Air Circuit Breaker Acb Factory, We adhere to client 1st, top quality 1st, continuous improvement, mutual advantage and win-win principles. When cooperation together with the customer, we deliver shoppers with the highest high-quality of service. Established good business relations using the Zimbabwe buyer inside the business, we’ve got established own brand and reputation. At the identical time, wholeheartedly welcome new and old prospects to our company to go to and negotiate small business.
Model No | RDW5-1600 | RDW5-2500 | RDWH-3200 | RDW5-4000 | RDW5-6300 | |||||
Rated current (A) | 200,400,630,800 1000,1250,1600 |
1000,1250,1600, 2000,2500 | 2000,2500,2900 3200,3600,4000 |
3200,3600,4000 | 400,050,006,300 | |||||
Neutral rated current In (A) | 100%In | 100%ln | 100%In | 100%In | 50%ln | |||||
Rated operating voltage (V) | AC400/690 | |||||||||
Frequency (Hz) | 50/60Hz | |||||||||
Number of poles | 3P/4P | |||||||||
Rated impulse withstand voltage Uimp(Kv) | Ad12 | |||||||||
Rated isolation voltage Ui(V) | AC 1000 | |||||||||
Power frequency withstand voltage (V) 1min | 3500 (Main circuit) | |||||||||
Rated ultimate short circuit breaking capacity (lcu) kA |
AC400V | 42 | 80 | 100 | 80 | |||||
AC690V | - | 50 | 65 | - | ||||||
Rated operating short circuit breaking capacity (lcs) kA |
AC400V | 32 | 65 | 80 | 65 | |||||
AC690V | - | 50 | 65 | - | ||||||
Rated withstand current for short- time (Icw) 1s(kA) |
AC400V | 20/30(0.5s) | 65 | 80 | 65 | |||||
AC690V | - | 40 | 50 | - | ||||||
Rated short circuit connection ability (Icm) kA | Electrical life | 7000 | 6500 | 3000 | 3000 | |||||
Mechanical life | 15000 | 15000 | 10000 | 10000 | ||||||
Using type | B type | |||||||||
Breaking time (without any auxiliary delay) | 25-30ms | |||||||||
Closing time | ≤70ms | |||||||||
Operation life (times) 2500A below | 400V electrical life |
8000 | 8000 | 5000 | 1500 | |||||
690V electrical life |
3000 | 2500 | 2000 | 1000 | ||||||
1time/3min; Above 2500A 1time/6min |
Mechanical life (maintenance-free) |
15000 | 12500 | 10000 | 6500 | |||||
Mechanical life (maintenance) |
30000 | 25000 | 20000 | 13000 | ||||||
Wire incoming pattern | Wire to enter from the upper or lower port | |||||||||
Arc distance (mm) | 0 | |||||||||
Installation method | Fixed type or draw-out type |
Draw-out type | Fixed type | ||||||||
Model | Poles | Width (mm) |
Height (mm) |
Depth mm) |
Weight (kg) |
Width (mm) |
Height (mm) |
Depth (mm) |
Weight (kg) |
RDW5-1600 | 3P | 282 | 351 | 345 | 43 | 254 | 320 | 254 | 22 |
4P | 352 | 351 | 345 | 55 | 324 | 320 | 254 | 26.5 | |
RDW5-2500 | 3P | 375 | 435 | 485 | 84 | 368 | 400 | 360 | 47 |
4P | 470 | 435 | 485 | 96 | 463 | 400 | 360 | 56 | |
RDW5-4000 | 3P | 435 | 435 | 515 | 100 | 428 | 400 | 392 | 53 |
4P | 550 | 435 | 515 | 130 | 543 | 400 | 392 | 67 | |
RDW5-6300 | 3P | 780 | 435 | 515 | 195 | 773 | 400 | 441 | 106 |
4P | 895 | 435 | 515 | 225 | 888 | 400 | 441 | 120 |
Overall dimension | Horizontal connection and overall dimension |
RDW5-6300/3P Fixed type horizontal connection | Horizontal connection and phase spacing |
Installation dimension | The relationship with busbar thickness and current | |
Rated current A | Busbar thickness mm | |
4000 | 20 | |
50006300 | 30 |
Overall dimension | Horizontal connection and overall dimension |
RDW5-6300/4P Fixed type horizontal connection | Horizontal connection and phase spacing |
Doorframe installation dimension of RDW5-4000-6300 fixed type | Installation dimension |
Overall dimension | Horizontal connection and phase spacing | Installation dimension |
RDW5-6300/3P The vertical connection of fixed type | Vertical connection and phase spacing |
Overall dimension | Horizontal connection and overall dimension | Installation dimension |
RDW5-6300/4P The horizontal connection of fixed type | Horizontal connection and phase spacing |
RDW5-6300/4P The vertical connection of fixed type | Vertical connection and phase spacing |
Model No | RDW5-1600 | RDW5-2500 | RDWH-3200 | RDW5-4000 | RDW5-6300 | |||||
Rated current (A) | 200,400,630,800 1000,1250,1600 |
1000,1250,1600, 2000,2500 | 2000,2500,2900 3200,3600,4000 |
3200,3600,4000 | 400,050,006,300 | |||||
Neutral rated current In (A) | 100%In | 100%ln | 100%In | 100%In | 50%ln | |||||
Rated operating voltage (V) | AC400/690 | |||||||||
Frequency (Hz) | 50/60Hz | |||||||||
Number of poles | 3P/4P | |||||||||
Rated impulse withstand voltage Uimp(Kv) | Ad12 | |||||||||
Rated isolation voltage Ui(V) | AC 1000 | |||||||||
Power frequency withstand voltage (V) 1min | 3500 (Main circuit) | |||||||||
Rated ultimate short circuit breaking capacity (lcu) kA |
AC400V | 42 | 80 | 100 | 80 | |||||
AC690V | - | 50 | 65 | - | ||||||
Rated operating short circuit breaking capacity (lcs) kA |
AC400V | 32 | 65 | 80 | 65 | |||||
AC690V | - | 50 | 65 | - | ||||||
Rated withstand current for short- time (Icw) 1s(kA) |
AC400V | 20/30(0.5s) | 65 | 80 | 65 | |||||
AC690V | - | 40 | 50 | - | ||||||
Rated short circuit connection ability (Icm) kA | Electrical life | 7000 | 6500 | 3000 | 3000 | |||||
Mechanical life | 15000 | 15000 | 10000 | 10000 | ||||||
Using type | B type | |||||||||
Breaking time (without any auxiliary delay) | 25-30ms | |||||||||
Closing time | ≤70ms | |||||||||
Operation life (times) 2500A below | 400V electrical life |
8000 | 8000 | 5000 | 1500 | |||||
690V electrical life |
3000 | 2500 | 2000 | 1000 | ||||||
1time/3min; Above 2500A 1time/6min |
Mechanical life (maintenance-free) |
15000 | 12500 | 10000 | 6500 | |||||
Mechanical life (maintenance) |
30000 | 25000 | 20000 | 13000 | ||||||
Wire incoming pattern | Wire to enter from the upper or lower port | |||||||||
Arc distance (mm) | 0 | |||||||||
Installation method | Fixed type or draw-out type |
Draw-out type | Fixed type | ||||||||
Model | Poles | Width (mm) |
Height (mm) |
Depth mm) |
Weight (kg) |
Width (mm) |
Height (mm) |
Depth (mm) |
Weight (kg) |
RDW5-1600 | 3P | 282 | 351 | 345 | 43 | 254 | 320 | 254 | 22 |
4P | 352 | 351 | 345 | 55 | 324 | 320 | 254 | 26.5 | |
RDW5-2500 | 3P | 375 | 435 | 485 | 84 | 368 | 400 | 360 | 47 |
4P | 470 | 435 | 485 | 96 | 463 | 400 | 360 | 56 | |
RDW5-4000 | 3P | 435 | 435 | 515 | 100 | 428 | 400 | 392 | 53 |
4P | 550 | 435 | 515 | 130 | 543 | 400 | 392 | 67 | |
RDW5-6300 | 3P | 780 | 435 | 515 | 195 | 773 | 400 | 441 | 106 |
4P | 895 | 435 | 515 | 225 | 888 | 400 | 441 | 120 |
Overall dimension | Horizontal connection and overall dimension |
RDW5-6300/3P Fixed type horizontal connection | Horizontal connection and phase spacing |
Installation dimension | The relationship with busbar thickness and current | |
Rated current A | Busbar thickness mm | |
4000 | 20 | |
50006300 | 30 |
Overall dimension | Horizontal connection and overall dimension |
RDW5-6300/4P Fixed type horizontal connection | Horizontal connection and phase spacing |
Doorframe installation dimension of RDW5-4000-6300 fixed type | Installation dimension |
Overall dimension | Horizontal connection and phase spacing | Installation dimension |
RDW5-6300/3P The vertical connection of fixed type | Vertical connection and phase spacing |
Overall dimension | Horizontal connection and overall dimension | Installation dimension |
RDW5-6300/4P The horizontal connection of fixed type | Horizontal connection and phase spacing |
RDW5-6300/4P The vertical connection of fixed type | Vertical connection and phase spacing |