Original Factory Mccb Mccb 4 Pole Enclosure 300 Amp DC Solar MCCB Circuit Breaker 250amp For Batteries

RDM5 series moulded case circuit breaker is applied to the circuit of AC 50HZ, insulation voltage 1000V, rated working voltage up to 690V, rated current up to 800A,which to distribute the power and protect the circuit and power source against overload , short-circuit and under voltage damage. Especially, when the current is lower 630A, it also can protect the motor. Normally breaker can infrequently invert and starting of motor. The product can be installed vertically and horizontally


  • Original Factory Mccb Mccb 4 Pole Enclosure 300 Amp DC Solar MCCB Circuit Breaker 250amp For Batteries
  • Original Factory Mccb Mccb 4 Pole Enclosure 300 Amp DC Solar MCCB Circuit Breaker 250amp For Batteries
  • Original Factory Mccb Mccb 4 Pole Enclosure 300 Amp DC Solar MCCB Circuit Breaker 250amp For Batteries
  • Original Factory Mccb Mccb 4 Pole Enclosure 300 Amp DC Solar MCCB Circuit Breaker 250amp For Batteries

Product Detail

Application

Parameters

Samples & Structures

Dimensions

We emphasize development and introduce new products into the market every year for Original Factory Mccb Mccb 4 Pole Enclosure 300 Amp DC Solar MCCB Circuit Breaker 250amp For Batteries, We adhere to your tenet of “Services of Standardization, to satisfy Customers’ Demands”.
We emphasize development and introduce new products into the market every year for , Our company is working by the operation principle of “integrity-based, cooperation created, people oriented, win-win cooperation”. We hope we can have a friendly relationship with businessman from all over the world.

Product Introduction

RDM5 series moulded case circuit breaker is applied to the circuit of AC 50HZ, insulation voltage 1000V, rated working voltage up to 690V, rated current up to 800A,which to distribute the power and protect the circuit and power source against overload , short-circuit and under voltage damage. Especially, when the current is lower 630A, it also can protect the motor. Normally breaker can infrequently invert and starting of motor. The product can be installed vertically and horizontally

Features

1.Panel Modular Disassembly Design

2.Boxed accessory design,easy installation

3.Ultimate Breaking Ability

4.Compact Size

5.The rated short-circuit breaking current Ics is 10ka higher than the traditional product RDM1′s highest breaking capacity

6.RDM5 durable service lifeWe emphasize development and introduce new products into the market every year for Original Factory Mccb Mccb 4 Pole Enclosure 300 Amp DC Solar MCCB Circuit Breaker 250amp For Batteries, We adhere to your tenet of “Services of Standardization, to satisfy Customers’ Demands”.
Original Factory , Our company is working by the operation principle of “integrity-based, cooperation created, people oriented, win-win cooperation”. We hope we can have a friendly relationship with businessman from all over the world.

Paraphrase
1 Trademark
2 Product model
3 Technical Parameters
4 Standard
5 CCC Certification mark
6 Company Name
7 Handle
8 Terminal screw
9 Trip button
10 Cover
11 Middle cover
12 Accessory mounting holes
13 Base
17

Upper
Casing

 

 

 

Middle
Piece

 

 

 

Lower
Casing

 

 

18

The product adopts double-layer insulationdesign to improve the safety of users.

19
20
Rated limit short-circuit breaking Icu up to 100ka, suitable for a variety of electrical places
21
22

· 6kA breaking capacity is needed during bidding and tendering,
4.5kA cannot meet the requirements of times any more
· All-series consistent 6kA breaking capacity, more excellent performance
· Meet the customers’ requirement for 50A and 63A breaking capacity
· Power consumption is far below the national standard requirement

23

63/100/125type

>Standard Cabinet: Greatsafety distance                                                   >Non-standard Cabinet: Saving oncabinet cost

24

The rated short-circuit breaking

current Ics is 10ka higher than the

traditional product RDM1′s highest

breakingcapacity, which effectively

improves the product

safetyperformance and meets the

high demand of customers.

25

26

Frame grade rated current l nm(A) 63 125 160 250 400 630 800
Rated currentln(A) 10、16、20、25、32、40、50、63 10、16、20、25、32、40、50、63、80、100、125 63、80、100、125、160 100、125、160、180、200、225、250 200、225、250、315、350、400 400、500、630 630、700、800
Pole(P) 2、3、4 3、4/2、3、4/3、4 3、4/2、3、4 3、4/2、3、4/3、4 3、4
Rated frequency(Hz) 50
Rated insulation voltageUi(V) AC1000
Rated impulse withstand voltage(V) 12000
Rated working voltageUe(V) 400V AC400/AC690
Arcing distance(mm) ≤50 ≤50 ≤50 ≤50 ≤100 ≤100 ≤100
Short-circuit breaking capacity L M S L M H S L M S L M H L M H S L M H L M H
Rated Limit/Rated breaking capacity lcu/lcs(AC400V) 25/15 35/25 25/18 50/35 70/50 100/70 25/18 35/23 50/35 25/18 50/35 70/50 100/70 50/50 70/70 100/75 50/35 50/50 70/70 100/75 65/65 75/75 100/75
Rated Limit/Rated breaking capacity lcu/lcs(AC690V) / / / 20/10. 20/12. 30/15. / 10/5. 15/8. / 20/10. 20/12. 30/15 20/10. 25/15 35/18 / 20/10. 25/15 35/18 20/10. 25/15 35/20
Use category A
Standards compliant IEC60947-2   GB/T14048-2
Suitable for working environment temperature -5℃+40℃
Electrical life(times) 8000 7500
Mechanical life(times) 20000 20000 20000 20000 10000 10000 10000
Shunt release
Undervoltage release
Alarm contact
Auxiliary contact

8

Shape and installation dimensions

27                                           28

 

                              2 poles                                                                                                                3 poles

30                                       31

 

                                        4 poles                                                                                                       Side

Product model Pole Front panel wiring Installation size Button position
L1 L2 L3 L4 L5 L6 W1 W2 W3 H1 H2 H3 H4 H5 H6 K a b d L7 L8
RDM5-63L/M
RDM5-125S/L
2 130.0 - 116.5 85.0 - 49.5 50.0 11.0 25.0 83.0 71.0 - 57.0 24.5 24.5 18.5 - 111.0 3.5 17.0 20.0
3 130.0 - 116.5 85.0 - 49.5 75.0 11.0 50.0 83.0 71.0 - 57.0 24.5 24.5 18.5 25.0 111.0 3.5 16.5 20.0
4 130.0 - 116.5 85.0 - 49.5 100.0 11.0 75.0 83.0 71.0 - 57.0 24.5 24.5 18.5 50.0 111.0 3.5 16.5 20.0
RDM5-125M/H 2 152.0 - 132.0 88.0 31.0 52.0  62 14.5 30.0 109.5 96.0 - 82.0 28.5 28.5 18.0 - 129.0 4.5 - 6.5
3 152.0 - 132.0 88.0 31.0 52.0  92 14.5 60.0 110.0 96.0 - 82.0 28.5 28.5 18.0 30.0 129.0 4.5 22.0 15.5
4 152.0 - 132.0 88.0 31.0 65.0 122.0 14.5 90.0 110.0 96.0 - 82.0 28.5 28.5 18.0 60.0 129.0 4.5 22.0 16.5
RDM5-160S/L/M 2 150.0 - 133.0 88.0 31.0 52.0  62 14.5 30.0 93.0 79.0 - 65.0 23.5 23.5 22.0 - 129.0 3.5 - 16.5
3 150.0 - 133.0 88.0 31.0 52.0  92 14.5 60.0 93.0 79.0 - 65.0 23.5 23.5 22.0 30.0 129.0 3.5 22.0 15.5
4 150.0 - 133.0 88.0 31.0 52.0 122.0 14.5 90.0 93.0 79.0 - 65.0 23.5 23.5 22.0 60.0 129.0 3.5 22.0 16.5
RDM5-250S/L 2 165.0 - 145.5 102.0 33.0 53.0 75.0 14.0 35.0 96.0 76.0 - 67.0  23 23.0 25.0 - 126.0 4.5 2.5 15.5
3 165.0 - 145.5 102.0 33.0 53.0 107.0 14.0 70.0 96.0 76.0 - 67.0  23 23.0 25.0 35.0 126.0 4.5 42.5 5.5
4 165.0 - 145.5 102.0 33.0 53.0 142.0 14.0 105.0 96.0 76.0 - 67.0  23 23.0 25.0 70.0 126.0 4.5 43.0 15.5
RDM5-250M/H 2 165.0 - 145.0 102.0 53.0 53.0 75.0 14.0 55.0 112.5 94.0 - 85.0  22 22.0 24.0 - 126.0 4.5 2.5 15.5
3 165.0 - 145.0 102.0 33.0 53.0 107.0 14.0 70.0 115.0 94.0 - 85.0  23 23.0 23.0 35.0 126.0 4.5 42.5 15.5
4 165.0 - 145.0 102.0 33.0 53.0 142.0 14.0 105.0 115.0 94.0 - 85.0  23 23.0 23.0 70.0 126.0 4.5 43.0 15.0
RDM5-400L/M/H
RDM5-630S
3 258.0 178.0 224.0 132.0 53.0 100.0 150.0 35.0 96.0 152.0 115.0 101.0 99.0  38 38.0 31.0 44.0 194.0 7.0 57.5 30.0
4 258.0 179.0 224.0 132.0 53.0 100.0 198.0 35.0 144.0 152.0 115.0 101.0 99.0  38 38.0 31.0 94.0 194.0 7.0 57.5 30.0
RDM5-630L/M/H 3 270.0 185.0 235.5 146.0 52.5 100.0 182.0 35.5 116.0 158.0 119.0 106.0 103.0  45 43.0 41.0 58.0 200.0 7.0 58.0 32.0
4 270.0 185.0 235.5 146.0 52.5 100.0 240.0 35.5 174.0 158.0 119.0 106.0 103.0  45 43.0 41.0 116.0 200.0 7.0 58.0 31.5
RDM5-800L/M/H 3 280.0 205.0 243.0 148.0 52.0 100.0 210.0 35.0 140.0 159.0 122.0 109.0 105.0 40.5 42.5 45.0 70.0 243.0 7.0 53.0 24.5
4 280.0 205.0 243.0 148.0 52.0 100.0 280.0 35.0 210.0 159.0 122.0 109.0 105.0 40.5 42.5 45.0 140.0 243.0 7.0 53.0 24.5

32

  Size code
(L11) W3 L9 L10
  RDM5-63L M
  RDM5-125S、L
  64 19 14 43
  RDM5-125M H
  RDM5-160S、L M
- 23 24 40
  RDM5-250S.L.M.H - 23 30 44
  RDM5-400L、M、H
  RDM5-630S
- 47 39 66
  RDM5-630L、M、H - 47 39 66
  RDM5-800L、M、H - 47 42 66

RDM5 series rear panel wiring installation panel opening size

33                                                            34

 

                              3 Poles                                                                                                                                    4 Poles

RDM5 series rear panel wiring appearance and installation dimensions

35                                                                         36

 

           RDM5- 125M/H 160、250                                                                                                        RDM5-400、630、800

RDM5-125~800 rear wiring appearance and mounting plate opening size

Product model Size code
H3 H4 D W L2 d2 A B C d1
RDM5-125M H 64 100 M8 50 132 24 30 108 60 5.5
RDM5-160L.M
RDM5-250L、M、H 70 100 M10 35 145 15 35 126 70 5.5
RDM5-400L.M、H
RDM5-630S
71 105.5 - 48 2242 32 44 194 94 7
RDM5-630L.M、H 46 105 - 58 2346 37 58 200 116 7
RDM5-800L,M.H 105 105 - 70 2436 48 70 243 70 7.5

RDM5 series plug-in front panel dimensions

37                                                                               38

 

Flat mount

Dimensions of RDM5-125~800 plug-in front panel circuit breaker

Product model Size code
A G K H H        ₂ Hs L1    L2 AM BM
RDM5-125M H 172 95 38.5 50.5 35   16.5 61 185   217 M6 M8
RDM5-160L,M
RDM5-250L,M、H 183 95 44 52 35   18 65 230   259 M6 M10
RDM5-400L,M,H
RDM5-630S
276 170 53 79.5 67   18 - 322   352 M6 M10
RDM5-630L,M、H 299 163.5 67.5 84.5 65.5   20 - 368   397 M8 M12
RDM5-80OL,M,H 303 179 62 87.5 60.5   28 118 375   405 M10 M12

Hole size of the plug-in front wiring mounting plate (X-XY-Y is the center of the circuit breaker)

40                                                                                     41

 

     Beam installation                                                                                                                Flat mount

RDM5-125~800 plug-in front wiring mounting plate opening size

Product model RDM5-125M.H
RDM5-160L.M
RDM5-250L.M,H RDM5-400L,M,H
RDM5-630S
RDM5-630L,M,H RDM5-800L,M.H
pole 3 3 3 3 3
Mounting plate opening size(mm) B 66 70 115 90.5 90.5
B1 50 60 - - 65
C 60 64 135 144.5 144.5
C1 35 35 - - 80
d 6.5 6.5 6.5 8.5 11

RDM5 series plug-in panel rear dimensions and mounting panel opening dimensions

42                                                                               43

 

Dimensions of RDM5-125~800 plug-in rear panel circuit breaker

Product model Size code
A F G K H H1 H2    H3 H4 AM BM
RDM5-125M H
RDM5-160L M
168 133 92 38 48 32.5 32.5 18 17 M6 M8
RDM5-25OL、M、H 186 144 95 45.5 49.5 33.5 34 15 17 M6 M8
RDM5-400L、M、H
RDM5-630S
280 224 171 54.5 59.5 40 44  23.5 20 M8 M12
RDM5-630L、M、H 300 234 170 65 59 40 50    30 20 M8 M12
RDM5-800L、M、H 305 243 181 62 87 60 - - 28 M10 M14

Hole size of plug-in rear wiring installation panel (X-XY-Y is the center of the circuit breaker)

44

RDM5-125~800 plug-in rear wiring installation panel opening size

Product model RDM5-125M.H
RDMS-160L.M
RDM5-25OL,M,H   RDM5-400L、M、H
  RDM5-630S
RDM5-630L  M.H RDM5-80OL. M.H
pole 3 4 3 4 3 4 3 4 3 4
Mounting plate opening size(mm) A 91 - 107 - 149 - 182 - 210 -
A1 - 129 - 145 - 200 - 242 - 290
B 60 - 70 - 60 - 100 - 90 -
B1 - 90 - 105 - 108 - 158 - 162
C 56 54 129 123 146
D 38 45.5 54.5 65 62
E 92 95 171 170 181
d 6.5 6.5 8.5 8.5 11
Paraphrase
1 Trademark
2 Product model
3 Technical Parameters
4 Standard
5 CCC Certification mark
6 Company Name
7 Handle
8 Terminal screw
9 Trip button
10 Cover
11 Middle cover
12 Accessory mounting holes
13 Base
17

Upper
Casing

 

 

 

Middle
Piece

 

 

 

Lower
Casing

 

 

18

The product adopts double-layer insulationdesign to improve the safety of users.

19
20
Rated limit short-circuit breaking Icu up to 100ka, suitable for a variety of electrical places
21
22

· 6kA breaking capacity is needed during bidding and tendering,
4.5kA cannot meet the requirements of times any more
· All-series consistent 6kA breaking capacity, more excellent performance
· Meet the customers’ requirement for 50A and 63A breaking capacity
· Power consumption is far below the national standard requirement

23

63/100/125type

>Standard Cabinet: Greatsafety distance                                                   >Non-standard Cabinet: Saving oncabinet cost

24

The rated short-circuit breaking

current Ics is 10ka higher than the

traditional product RDM1′s highest

breakingcapacity, which effectively

improves the product

safetyperformance and meets the

high demand of customers.

25

26

Frame grade rated current l nm(A) 63 125 160 250 400 630 800
Rated currentln(A) 10、16、20、25、32、40、50、63 10、16、20、25、32、40、50、63、80、100、125 63、80、100、125、160 100、125、160、180、200、225、250 200、225、250、315、350、400 400、500、630 630、700、800
Pole(P) 2、3、4 3、4/2、3、4/3、4 3、4/2、3、4 3、4/2、3、4/3、4 3、4
Rated frequency(Hz) 50
Rated insulation voltageUi(V) AC1000
Rated impulse withstand voltage(V) 12000
Rated working voltageUe(V) 400V AC400/AC690
Arcing distance(mm) ≤50 ≤50 ≤50 ≤50 ≤100 ≤100 ≤100
Short-circuit breaking capacity L M S L M H S L M S L M H L M H S L M H L M H
Rated Limit/Rated breaking capacity lcu/lcs(AC400V) 25/15 35/25 25/18 50/35 70/50 100/70 25/18 35/23 50/35 25/18 50/35 70/50 100/70 50/50 70/70 100/75 50/35 50/50 70/70 100/75 65/65 75/75 100/75
Rated Limit/Rated breaking capacity lcu/lcs(AC690V) / / / 20/10. 20/12. 30/15. / 10/5. 15/8. / 20/10. 20/12. 30/15 20/10. 25/15 35/18 / 20/10. 25/15 35/18 20/10. 25/15 35/20
Use category A
Standards compliant IEC60947-2   GB/T14048-2
Suitable for working environment temperature -5℃+40℃
Electrical life(times) 8000 7500
Mechanical life(times) 20000 20000 20000 20000 10000 10000 10000
Shunt release
Undervoltage release
Alarm contact
Auxiliary contact

8

Shape and installation dimensions

27                                           28

 

                              2 poles                                                                                                                3 poles

30                                       31

 

                                        4 poles                                                                                                       Side

Product model Pole Front panel wiring Installation size Button position
L1 L2 L3 L4 L5 L6 W1 W2 W3 H1 H2 H3 H4 H5 H6 K a b d L7 L8
RDM5-63L/M
RDM5-125S/L
2 130.0 - 116.5 85.0 - 49.5 50.0 11.0 25.0 83.0 71.0 - 57.0 24.5 24.5 18.5 - 111.0 3.5 17.0 20.0
3 130.0 - 116.5 85.0 - 49.5 75.0 11.0 50.0 83.0 71.0 - 57.0 24.5 24.5 18.5 25.0 111.0 3.5 16.5 20.0
4 130.0 - 116.5 85.0 - 49.5 100.0 11.0 75.0 83.0 71.0 - 57.0 24.5 24.5 18.5 50.0 111.0 3.5 16.5 20.0
RDM5-125M/H 2 152.0 - 132.0 88.0 31.0 52.0  62 14.5 30.0 109.5 96.0 - 82.0 28.5 28.5 18.0 - 129.0 4.5 - 6.5
3 152.0 - 132.0 88.0 31.0 52.0  92 14.5 60.0 110.0 96.0 - 82.0 28.5 28.5 18.0 30.0 129.0 4.5 22.0 15.5
4 152.0 - 132.0 88.0 31.0 65.0 122.0 14.5 90.0 110.0 96.0 - 82.0 28.5 28.5 18.0 60.0 129.0 4.5 22.0 16.5
RDM5-160S/L/M 2 150.0 - 133.0 88.0 31.0 52.0  62 14.5 30.0 93.0 79.0 - 65.0 23.5 23.5 22.0 - 129.0 3.5 - 16.5
3 150.0 - 133.0 88.0 31.0 52.0  92 14.5 60.0 93.0 79.0 - 65.0 23.5 23.5 22.0 30.0 129.0 3.5 22.0 15.5
4 150.0 - 133.0 88.0 31.0 52.0 122.0 14.5 90.0 93.0 79.0 - 65.0 23.5 23.5 22.0 60.0 129.0 3.5 22.0 16.5
RDM5-250S/L 2 165.0 - 145.5 102.0 33.0 53.0 75.0 14.0 35.0 96.0 76.0 - 67.0  23 23.0 25.0 - 126.0 4.5 2.5 15.5
3 165.0 - 145.5 102.0 33.0 53.0 107.0 14.0 70.0 96.0 76.0 - 67.0  23 23.0 25.0 35.0 126.0 4.5 42.5 5.5
4 165.0 - 145.5 102.0 33.0 53.0 142.0 14.0 105.0 96.0 76.0 - 67.0  23 23.0 25.0 70.0 126.0 4.5 43.0 15.5
RDM5-250M/H 2 165.0 - 145.0 102.0 53.0 53.0 75.0 14.0 55.0 112.5 94.0 - 85.0  22 22.0 24.0 - 126.0 4.5 2.5 15.5
3 165.0 - 145.0 102.0 33.0 53.0 107.0 14.0 70.0 115.0 94.0 - 85.0  23 23.0 23.0 35.0 126.0 4.5 42.5 15.5
4 165.0 - 145.0 102.0 33.0 53.0 142.0 14.0 105.0 115.0 94.0 - 85.0  23 23.0 23.0 70.0 126.0 4.5 43.0 15.0
RDM5-400L/M/H
RDM5-630S
3 258.0 178.0 224.0 132.0 53.0 100.0 150.0 35.0 96.0 152.0 115.0 101.0 99.0  38 38.0 31.0 44.0 194.0 7.0 57.5 30.0
4 258.0 179.0 224.0 132.0 53.0 100.0 198.0 35.0 144.0 152.0 115.0 101.0 99.0  38 38.0 31.0 94.0 194.0 7.0 57.5 30.0
RDM5-630L/M/H 3 270.0 185.0 235.5 146.0 52.5 100.0 182.0 35.5 116.0 158.0 119.0 106.0 103.0  45 43.0 41.0 58.0 200.0 7.0 58.0 32.0
4 270.0 185.0 235.5 146.0 52.5 100.0 240.0 35.5 174.0 158.0 119.0 106.0 103.0  45 43.0 41.0 116.0 200.0 7.0 58.0 31.5
RDM5-800L/M/H 3 280.0 205.0 243.0 148.0 52.0 100.0 210.0 35.0 140.0 159.0 122.0 109.0 105.0 40.5 42.5 45.0 70.0 243.0 7.0 53.0 24.5
4 280.0 205.0 243.0 148.0 52.0 100.0 280.0 35.0 210.0 159.0 122.0 109.0 105.0 40.5 42.5 45.0 140.0 243.0 7.0 53.0 24.5

32

  Size code
(L11) W3 L9 L10
  RDM5-63L M
  RDM5-125S、L
  64 19 14 43
  RDM5-125M H
  RDM5-160S、L M
- 23 24 40
  RDM5-250S.L.M.H - 23 30 44
  RDM5-400L、M、H
  RDM5-630S
- 47 39 66
  RDM5-630L、M、H - 47 39 66
  RDM5-800L、M、H - 47 42 66

RDM5 series rear panel wiring installation panel opening size

33                                                            34

 

                              3 Poles                                                                                                                                    4 Poles

RDM5 series rear panel wiring appearance and installation dimensions

35                                                                         36

 

           RDM5- 125M/H 160、250                                                                                                        RDM5-400、630、800

RDM5-125~800 rear wiring appearance and mounting plate opening size

Product model Size code
H3 H4 D W L2 d2 A B C d1
RDM5-125M H 64 100 M8 50 132 24 30 108 60 5.5
RDM5-160L.M
RDM5-250L、M、H 70 100 M10 35 145 15 35 126 70 5.5
RDM5-400L.M、H
RDM5-630S
71 105.5 - 48 2242 32 44 194 94 7
RDM5-630L.M、H 46 105 - 58 2346 37 58 200 116 7
RDM5-800L,M.H 105 105 - 70 2436 48 70 243 70 7.5

RDM5 series plug-in front panel dimensions

37                                                                               38

 

Flat mount

Dimensions of RDM5-125~800 plug-in front panel circuit breaker

Product model Size code
A G K H H        ₂ Hs L1    L2 AM BM
RDM5-125M H 172 95 38.5 50.5 35   16.5 61 185   217 M6 M8
RDM5-160L,M
RDM5-250L,M、H 183 95 44 52 35   18 65 230   259 M6 M10
RDM5-400L,M,H
RDM5-630S
276 170 53 79.5 67   18 - 322   352 M6 M10
RDM5-630L,M、H 299 163.5 67.5 84.5 65.5   20 - 368   397 M8 M12
RDM5-80OL,M,H 303 179 62 87.5 60.5   28 118 375   405 M10 M12

Hole size of the plug-in front wiring mounting plate (X-XY-Y is the center of the circuit breaker)

40                                                                                     41

 

     Beam installation                                                                                                                Flat mount

RDM5-125~800 plug-in front wiring mounting plate opening size

Product model RDM5-125M.H
RDM5-160L.M
RDM5-250L.M,H RDM5-400L,M,H
RDM5-630S
RDM5-630L,M,H RDM5-800L,M.H
pole 3 3 3 3 3
Mounting plate opening size(mm) B 66 70 115 90.5 90.5
B1 50 60 - - 65
C 60 64 135 144.5 144.5
C1 35 35 - - 80
d 6.5 6.5 6.5 8.5 11

RDM5 series plug-in panel rear dimensions and mounting panel opening dimensions

42                                                                               43

 

Dimensions of RDM5-125~800 plug-in rear panel circuit breaker

Product model Size code
A F G K H H1 H2    H3 H4 AM BM
RDM5-125M H
RDM5-160L M
168 133 92 38 48 32.5 32.5 18 17 M6 M8
RDM5-25OL、M、H 186 144 95 45.5 49.5 33.5 34 15 17 M6 M8
RDM5-400L、M、H
RDM5-630S
280 224 171 54.5 59.5 40 44  23.5 20 M8 M12
RDM5-630L、M、H 300 234 170 65 59 40 50    30 20 M8 M12
RDM5-800L、M、H 305 243 181 62 87 60 - - 28 M10 M14

Hole size of plug-in rear wiring installation panel (X-XY-Y is the center of the circuit breaker)

44

RDM5-125~800 plug-in rear wiring installation panel opening size

Product model RDM5-125M.H
RDMS-160L.M
RDM5-25OL,M,H   RDM5-400L、M、H
  RDM5-630S
RDM5-630L  M.H RDM5-80OL. M.H
pole 3 4 3 4 3 4 3 4 3 4
Mounting plate opening size(mm) A 91 - 107 - 149 - 182 - 210 -
A1 - 129 - 145 - 200 - 242 - 290
B 60 - 70 - 60 - 100 - 90 -
B1 - 90 - 105 - 108 - 158 - 162
C 56 54 129 123 146
D 38 45.5 54.5 65 62
E 92 95 171 170 181
d 6.5 6.5 8.5 8.5 11
Write your message here and send it to us