We take “customer-friendly, quality-oriented, integrative, innovative” as objectives. “Truth and honesty” is our management ideal for Factory Outlets 3p+1no/1nc Sliver Contact Relay Contactor Ui 690VAC with CE Approval, Our professional technical team will be wholeheartedly at your service. We sincerely welcome you to visit our website and company and send us your inquiry.
We take “customer-friendly, quality-oriented, integrative, innovative” as objectives. “Truth and honesty” is our management ideal for China AC Contactor and Contactor, As an experienced factory we also accept customized order and make it same as your picture or sample specifying specification and customer design packing. The main goal of the company is to live a satisfactory memory to all the customers, and establish a long term win-win business relationship. For more information, you should contact us. And It is our great pleasure if you like to have a personally meeting in our office.
RDC5 series AC contactor has 4 housing current levels, the optional current is from 6A to 95A, and the series increase two new currents (06A and 38A_ compared with CJX2 so as to meet different power distribution requirements.
The product has passed the national 3C certification, takes the lead of similar products in the industry and guarantees the safe and stable operation of power supply system.
1. High quality, withstand analysis
2. Ultra-strong voltage pull-in range
3. Excellent performance and ultra-long life
4. Humanized design and convenient installation
5. Perfect dust-proof effect, wider application scope
6. Supporting accessories and installation
Become a stage for employees to realize their dreams! Build a happier, more united and more professional team! We sincerely welcome foreign buyers to consult for long-term cooperation and mutual progress.
At a fixed competitive price, we have always adhered to the evolution of solutions, invested a lot of capital and human resources in technology upgrading, promoted production improvement, and met the needs of all countries and regions.
Our team has rich industry experience and high technical level. 80% of team members have more than 5 years of mechanical product service experience. Therefore, we are very confident to provide you with the best quality and service. Over the years, the company has been praised and appreciated by new and old customers for its purpose of “high-quality and perfect service”We take “customer-friendly, quality-oriented, integrative, innovative” as objectives. “Truth and honesty” is our management ideal for Factory Outlets 3p+1no/1nc Sliver Contact Relay Contactor Ui 690VAC with CE Approval, Our professional technical team will be wholeheartedly at your service. We sincerely welcome you to visit our website and company and send us your inquiry.
Factory Outlets China AC Contactor and Contactor, As an experienced factory we also accept customized order and make it same as your picture or sample specifying specification and customer design packing. The main goal of the company is to live a satisfactory memory to all the customers, and establish a long term win-win business relationship. For more information, you should contact us. And It is our great pleasure if you like to have a personally meeting in our office.
The switch is one of the essential electrical equipment in the home and business place. High-quality switches can not only provide convenient electrical control, but also ensure the safety of users. Our products have the following characteristics:
1. High quality insulating materials: high-quality switches usually use high-quality insulating materials, which can effectively isolate current, prevent current leakage and ensure the personal safety of users. Compared with low-quality switches, high-quality switches have a longer service life and can better withstand the test of time and use.
2. Simple installation and easy operation: high-quality switches are usually simple in design and easy to install. Even without the help of professional electricians, users can easily complete the installation. In addition, these switches are also very easy to operate. Users can easily control the switches of electrical equipment without fear of danger.
3. Multiple safety protection measures: high-quality switches usually have multiple safety protection measures, such as protection against overload, short circuit, leakage and other safety functions. These protective measures can avoid the danger caused by accidental damage of electrical equipment and protect the safety of users and electrical equipment itself.
4. Certified, high compliance: high-quality switches are usually certified by various authorities, such as CE certification, UL certification, etc. These certifications prove that the switch complies with international safety standards and has high compliance. Using these certified switches can help users reduce risks and gain a safer use experience.
70%-120%Us voltage pull-in range
Surpass similar products 20%
RDC5 has upper and lower wiring terminals so that the user can connect wires more quickly and safely.
Perfect dust-proof effect, applicable to various operating environment.
Product Model |
RDC5-06 |
RDC5-09 |
RDC5-12 |
RDC5-18 |
RDC5-25 |
RDC5-32 |
RDC5-38 |
RDC5-40 |
RDC5-50 |
RDC5-65 |
RDC5-80 |
RDC5-95
|
||||||||||||||||||||||||||||||||||||||
Number of pole |
3 poles |
|||||||||||||||||||||||||||||||||||||||||||||||||
Rated insulation Voltage(Ui)V |
690
|
|||||||||||||||||||||||||||||||||||||||||||||||||
Rated operating voltage(Ue)V |
380/400, 660/690 |
|||||||||||||||||||||||||||||||||||||||||||||||||
Conventional heating current(Ith)A |
16 |
20 |
20 |
25 |
32 |
40 |
40 |
50 |
60 |
80 |
110 |
110
|
||||||||||||||||||||||||||||||||||||||
Rated current (le)A |
AC-3 |
380/400V |
6 |
9 |
12 |
18 |
25 |
32 |
38 |
40 |
50 |
65 |
80 |
95 |
||||||||||||||||||||||||||||||||||||
660/690V |
3.8 |
6.6 |
8.9 |
12 |
18 |
22 |
22 |
34 |
39 |
42 |
49 |
49 |
||||||||||||||||||||||||||||||||||||||
AC-4 |
380/400V |
2.6 |
3.5 |
5 |
7.7 |
8.5 |
12 |
14 |
18.5 |
24 |
28 |
37 |
44 |
|||||||||||||||||||||||||||||||||||||
660/690V |
1 |
1.5 |
2 |
3.8 |
4.4 |
7.5 |
8.9 |
9 |
12 |
14 |
17.3 |
21.3 |
||||||||||||||||||||||||||||||||||||||
Rated Power (PE)KW |
AC-3 |
380/400V |
2.2 |
4 |
5.5 |
7.5 |
11 |
15 |
18.5 |
18.5 |
22 |
30 |
37 |
45 |
||||||||||||||||||||||||||||||||||||
660/690V |
3 |
5.5 |
7.5 |
10 |
15 |
18.8 |
18.5 |
30 |
33 |
37 |
45 |
45 |
||||||||||||||||||||||||||||||||||||||
AC-4 |
380/400V |
1.1 |
1.5 |
2.2 |
3.3 |
4 |
5.4 |
5.5 |
7.5 |
11 |
15 |
18.5 |
22 |
|||||||||||||||||||||||||||||||||||||
660/690V |
0.75 |
1.1 |
1.5 |
3 |
3.7 |
5.5 |
6 |
7.5 |
10 |
11 |
15 |
18.5 |
||||||||||||||||||||||||||||||||||||||
Mechanical life(10000 times/h) |
1200 |
1000 |
900 |
650 |
||||||||||||||||||||||||||||||||||||||||||||||
Electrical life |
AC-3(10000times/h) |
110 |
90 |
65 |
||||||||||||||||||||||||||||||||||||||||||||||
AC-4(10000times/h) |
22 |
22 |
17 |
11 |
||||||||||||||||||||||||||||||||||||||||||||||
Operation frequency |
AC-3(times/h) |
1200 |
600 |
|||||||||||||||||||||||||||||||||||||||||||||||
AC-4(times/h) |
300 |
|||||||||||||||||||||||||||||||||||||||||||||||||
Coil |
Rared control voltage Us(V) |
AC 24,36,48,110,127,220/230,240,380/400,415,440 |
||||||||||||||||||||||||||||||||||||||||||||||||
Pull-in voltage 50/60HZ V |
(0.85-1.1)Us |
|||||||||||||||||||||||||||||||||||||||||||||||||
Release voltage 50/60Hz V |
(0.2-0.7)Us |
|||||||||||||||||||||||||||||||||||||||||||||||||
Coil power consum-ption |
Pull-in VA |
50 |
60 |
70 |
200 |
200 |
||||||||||||||||||||||||||||||||||||||||||||
Hold VA |
6-9 |
6-9.5 |
6-9.5 |
15-20 |
15-20 |
|||||||||||||||||||||||||||||||||||||||||||||
Power W |
1-3 |
1-3 |
1-3 |
6-10 |
6-10 |
|||||||||||||||||||||||||||||||||||||||||||||
Pieces mm² |
1 |
2 |
1 |
2 |
1 |
2 |
1 |
2 |
1 |
2 |
1 |
2 |
1 |
2 |
1 |
2 |
1 |
2 |
1 |
2 |
1 |
2 |
1 |
2 |
||||||||||||||||||||||||||
Terminals |
Flexible wire with terminal mm² |
4 |
2.5 |
4 |
2.5 |
4 |
2.5 |
4 |
2.5 |
6 |
4 |
6 |
4 |
6 |
4 |
25 |
10 |
25 |
10 |
25 |
10 |
50 |
16 |
50 |
16 |
|||||||||||||||||||||||||
Flexible wire without terminal mm² |
4 |
4 |
4 |
4 |
4 |
4 |
4 |
4 |
6 |
6 |
6 |
6 |
6 |
6 |
25 |
16 |
25 |
16 |
25 |
16 |
50 |
25 |
50 |
25 |
||||||||||||||||||||||||||
Hard wire mm² |
4 |
4 |
4 |
4 |
4 |
4 |
6 |
6 |
6 |
6 |
10 |
6 |
10 |
6 |
25 |
10 |
25 |
10 |
25 |
10 |
50 |
25 |
50 |
25 |
||||||||||||||||||||||||||
Tightening torque |
(N*m) |
1.2 |
1.8 |
5 |
9 |
|||||||||||||||||||||||||||||||||||||||||||||
Suited fuse type |
Model |
RDT16(NT)-00 |
||||||||||||||||||||||||||||||||||||||||||||||||
Rated current(A) |
16 |
20 |
20 |
32 |
40 |
50 |
63 |
63 |
80 |
80 |
100 |
125
|
||||||||||||||||||||||||||||||||||||||
Suited thermal relay |
RDR5-25 |
RDR5-25 |
RDR5-25 |
RDR5-25 |
RDR5-25 |
RDR5-25 RDR5-36 |
RDR5-25 RDR5-36 |
RDR5-93 |
RDR5-93 |
RDR5-93 |
RDR5-93 |
RDR5-93 |
||||||||||||||||||||||||||||||||||||||
Auxiliary contacts |
Can be added with F4,LA8 auxiliary contacts, LA-D/LA3-D type air delay contacts |
Model | Amax | Bmax | B1max | B2max | Cmax | C1max | C2max | ||||||
RDC5-06,09,12,18 | 74.5 | 45.5 | 58 | 71 | 82.5 | 114.5 | 139.5 | ||||||
RDC5-25,32,38 | 83 | 56.5 | 69 | 82 | 97 | 129 | 154 | ||||||
RDC5-40,50,65 | 127.5 | 74.5 | 88 | 101 | 117 | 148.5 | 173.5 | ||||||
RDC5-80.95 | 127.5 | 85.5 | 99 | 112 | 125.5 | 157 | 182 | ||||||
Note: | B1max=contactor+LA8; B2max=contactor+2×LA8; C1max=contactor+F4; C2max=contactor+LA2(3)D |
Model | a | b | c | d | e | f | ||||||
RDC5-06,09,12,18 | 35 | 50/60 | - | - | - | - | ||||||
RDC5-25,32,38 | 40 | 50/60 | - | - | - | - | ||||||
RDC5-40,50,65 | - | - | 105 | 40 | 100/110 | 59 | ||||||
RDC5-80.95 | - | - | 105 | 40 | 100/110 | 67 |
Normal operating condition and installation condition
3.1Ambienttemperature:+5℃~+40℃averaae temperature within 24h does notexceed+35℃
3.2Altitude:doesnotexceed2000m
3.3 Atmospheric condition:when the highest temperature is +40℃the relativelv humidity does not exceed 50%;it can allow relatively high humidity when it is at relatively low temperature, for
instance. it reaches 90% whenit is at+20it should take measurement when there have
condensation occurred due to thetemperature variation.
3.4 Pollution grade:3
3.5Installation categorv:l
3.6 Installation position: the aradient of the mountina surface to the vertical surface does no exceed+5°
3.7lmpact andvibration: product should be installed and used at the places without obvious shake impact and vibration.
The switch is one of the essential electrical equipment in the home and business place. High-quality switches can not only provide convenient electrical control, but also ensure the safety of users. Our products have the following characteristics:
1. High quality insulating materials: high-quality switches usually use high-quality insulating materials, which can effectively isolate current, prevent current leakage and ensure the personal safety of users. Compared with low-quality switches, high-quality switches have a longer service life and can better withstand the test of time and use.
2. Simple installation and easy operation: high-quality switches are usually simple in design and easy to install. Even without the help of professional electricians, users can easily complete the installation. In addition, these switches are also very easy to operate. Users can easily control the switches of electrical equipment without fear of danger.
3. Multiple safety protection measures: high-quality switches usually have multiple safety protection measures, such as protection against overload, short circuit, leakage and other safety functions. These protective measures can avoid the danger caused by accidental damage of electrical equipment and protect the safety of users and electrical equipment itself.
4. Certified, high compliance: high-quality switches are usually certified by various authorities, such as CE certification, UL certification, etc. These certifications prove that the switch complies with international safety standards and has high compliance. Using these certified switches can help users reduce risks and gain a safer use experience.
70%-120%Us voltage pull-in range
Surpass similar products 20%
RDC5 has upper and lower wiring terminals so that the user can connect wires more quickly and safely.
Perfect dust-proof effect, applicable to various operating environment.
Product Model |
RDC5-06 |
RDC5-09 |
RDC5-12 |
RDC5-18 |
RDC5-25 |
RDC5-32 |
RDC5-38 |
RDC5-40 |
RDC5-50 |
RDC5-65 |
RDC5-80 |
RDC5-95
|
||||||||||||||||||||||||||||||||||||||
Number of pole |
3 poles |
|||||||||||||||||||||||||||||||||||||||||||||||||
Rated insulation Voltage(Ui)V |
690
|
|||||||||||||||||||||||||||||||||||||||||||||||||
Rated operating voltage(Ue)V |
380/400, 660/690 |
|||||||||||||||||||||||||||||||||||||||||||||||||
Conventional heating current(Ith)A |
16 |
20 |
20 |
25 |
32 |
40 |
40 |
50 |
60 |
80 |
110 |
110
|
||||||||||||||||||||||||||||||||||||||
Rated current (le)A |
AC-3 |
380/400V |
6 |
9 |
12 |
18 |
25 |
32 |
38 |
40 |
50 |
65 |
80 |
95 |
||||||||||||||||||||||||||||||||||||
660/690V |
3.8 |
6.6 |
8.9 |
12 |
18 |
22 |
22 |
34 |
39 |
42 |
49 |
49 |
||||||||||||||||||||||||||||||||||||||
AC-4 |
380/400V |
2.6 |
3.5 |
5 |
7.7 |
8.5 |
12 |
14 |
18.5 |
24 |
28 |
37 |
44 |
|||||||||||||||||||||||||||||||||||||
660/690V |
1 |
1.5 |
2 |
3.8 |
4.4 |
7.5 |
8.9 |
9 |
12 |
14 |
17.3 |
21.3 |
||||||||||||||||||||||||||||||||||||||
Rated Power (PE)KW |
AC-3 |
380/400V |
2.2 |
4 |
5.5 |
7.5 |
11 |
15 |
18.5 |
18.5 |
22 |
30 |
37 |
45 |
||||||||||||||||||||||||||||||||||||
660/690V |
3 |
5.5 |
7.5 |
10 |
15 |
18.8 |
18.5 |
30 |
33 |
37 |
45 |
45 |
||||||||||||||||||||||||||||||||||||||
AC-4 |
380/400V |
1.1 |
1.5 |
2.2 |
3.3 |
4 |
5.4 |
5.5 |
7.5 |
11 |
15 |
18.5 |
22 |
|||||||||||||||||||||||||||||||||||||
660/690V |
0.75 |
1.1 |
1.5 |
3 |
3.7 |
5.5 |
6 |
7.5 |
10 |
11 |
15 |
18.5 |
||||||||||||||||||||||||||||||||||||||
Mechanical life(10000 times/h) |
1200 |
1000 |
900 |
650 |
||||||||||||||||||||||||||||||||||||||||||||||
Electrical life |
AC-3(10000times/h) |
110 |
90 |
65 |
||||||||||||||||||||||||||||||||||||||||||||||
AC-4(10000times/h) |
22 |
22 |
17 |
11 |
||||||||||||||||||||||||||||||||||||||||||||||
Operation frequency |
AC-3(times/h) |
1200 |
600 |
|||||||||||||||||||||||||||||||||||||||||||||||
AC-4(times/h) |
300 |
|||||||||||||||||||||||||||||||||||||||||||||||||
Coil |
Rared control voltage Us(V) |
AC 24,36,48,110,127,220/230,240,380/400,415,440 |
||||||||||||||||||||||||||||||||||||||||||||||||
Pull-in voltage 50/60HZ V |
(0.85-1.1)Us |
|||||||||||||||||||||||||||||||||||||||||||||||||
Release voltage 50/60Hz V |
(0.2-0.7)Us |
|||||||||||||||||||||||||||||||||||||||||||||||||
Coil power consum-ption |
Pull-in VA |
50 |
60 |
70 |
200 |
200 |
||||||||||||||||||||||||||||||||||||||||||||
Hold VA |
6-9 |
6-9.5 |
6-9.5 |
15-20 |
15-20 |
|||||||||||||||||||||||||||||||||||||||||||||
Power W |
1-3 |
1-3 |
1-3 |
6-10 |
6-10 |
|||||||||||||||||||||||||||||||||||||||||||||
Pieces mm² |
1 |
2 |
1 |
2 |
1 |
2 |
1 |
2 |
1 |
2 |
1 |
2 |
1 |
2 |
1 |
2 |
1 |
2 |
1 |
2 |
1 |
2 |
1 |
2 |
||||||||||||||||||||||||||
Terminals |
Flexible wire with terminal mm² |
4 |
2.5 |
4 |
2.5 |
4 |
2.5 |
4 |
2.5 |
6 |
4 |
6 |
4 |
6 |
4 |
25 |
10 |
25 |
10 |
25 |
10 |
50 |
16 |
50 |
16 |
|||||||||||||||||||||||||
Flexible wire without terminal mm² |
4 |
4 |
4 |
4 |
4 |
4 |
4 |
4 |
6 |
6 |
6 |
6 |
6 |
6 |
25 |
16 |
25 |
16 |
25 |
16 |
50 |
25 |
50 |
25 |
||||||||||||||||||||||||||
Hard wire mm² |
4 |
4 |
4 |
4 |
4 |
4 |
6 |
6 |
6 |
6 |
10 |
6 |
10 |
6 |
25 |
10 |
25 |
10 |
25 |
10 |
50 |
25 |
50 |
25 |
||||||||||||||||||||||||||
Tightening torque |
(N*m) |
1.2 |
1.8 |
5 |
9 |
|||||||||||||||||||||||||||||||||||||||||||||
Suited fuse type |
Model |
RDT16(NT)-00 |
||||||||||||||||||||||||||||||||||||||||||||||||
Rated current(A) |
16 |
20 |
20 |
32 |
40 |
50 |
63 |
63 |
80 |
80 |
100 |
125
|
||||||||||||||||||||||||||||||||||||||
Suited thermal relay |
RDR5-25 |
RDR5-25 |
RDR5-25 |
RDR5-25 |
RDR5-25 |
RDR5-25 RDR5-36 |
RDR5-25 RDR5-36 |
RDR5-93 |
RDR5-93 |
RDR5-93 |
RDR5-93 |
RDR5-93 |
||||||||||||||||||||||||||||||||||||||
Auxiliary contacts |
Can be added with F4,LA8 auxiliary contacts, LA-D/LA3-D type air delay contacts |
Model | Amax | Bmax | B1max | B2max | Cmax | C1max | C2max | ||||||
RDC5-06,09,12,18 | 74.5 | 45.5 | 58 | 71 | 82.5 | 114.5 | 139.5 | ||||||
RDC5-25,32,38 | 83 | 56.5 | 69 | 82 | 97 | 129 | 154 | ||||||
RDC5-40,50,65 | 127.5 | 74.5 | 88 | 101 | 117 | 148.5 | 173.5 | ||||||
RDC5-80.95 | 127.5 | 85.5 | 99 | 112 | 125.5 | 157 | 182 | ||||||
Note: | B1max=contactor+LA8; B2max=contactor+2×LA8; C1max=contactor+F4; C2max=contactor+LA2(3)D |
Model | a | b | c | d | e | f | ||||||
RDC5-06,09,12,18 | 35 | 50/60 | - | - | - | - | ||||||
RDC5-25,32,38 | 40 | 50/60 | - | - | - | - | ||||||
RDC5-40,50,65 | - | - | 105 | 40 | 100/110 | 59 | ||||||
RDC5-80.95 | - | - | 105 | 40 | 100/110 | 67 |
Normal operating condition and installation condition
3.1Ambienttemperature:+5℃~+40℃averaae temperature within 24h does notexceed+35℃
3.2Altitude:doesnotexceed2000m
3.3 Atmospheric condition:when the highest temperature is +40℃the relativelv humidity does not exceed 50%;it can allow relatively high humidity when it is at relatively low temperature, for
instance. it reaches 90% whenit is at+20it should take measurement when there have
condensation occurred due to thetemperature variation.
3.4 Pollution grade:3
3.5Installation categorv:l
3.6 Installation position: the aradient of the mountina surface to the vertical surface does no exceed+5°
3.7lmpact andvibration: product should be installed and used at the places without obvious shake impact and vibration.