Discount Price Professional Moulded Case Circuit Breaker Manufacturer AC DC 16- 160AMP Low Voltage Protector RCCB/RCBO/ELCB/MCB/MCCB

RDM5 series plastic case circuit breakers are mainly used in power distribution networks with AC 50Hz, rated insulation voltage of 1000V, rated working voltage of 690V and below, and rated current below 800A to distribute electric energy and protect lines and power equipment from overload and short circuit. and damage caused by faults such as undervoltage. Among them, the circuit breaker with rated current of 630A and below can also be used to protect the motor. Under normal circumstances, the circuit breaker can be used for the infrequent switching of the line and the infrequent starting of the electric scooter. The product conforms to: GB/T 14048.2 standard.


  • Discount Price Professional Moulded Case Circuit Breaker Manufacturer AC DC 16- 160AMP Low Voltage Protector RCCB/RCBO/ELCB/MCB/MCCB
  • Discount Price Professional Moulded Case Circuit Breaker Manufacturer AC DC 16- 160AMP Low Voltage Protector RCCB/RCBO/ELCB/MCB/MCCB

Product Detail

Application

Parameters

Samples & Structures

Dimensions

We take “customer-friendly, quality-oriented, integrative, innovative” as objectives. “Truth and honesty” is our administration ideal for Discount Price Professional Moulded Case Circuit Breaker Manufacturer AC DC 16- 160AMP Low Voltage Protector RCCB/RCBO/ELCB/MCB/MCCB, We’ll do our greatest to fulfill your specifications and are sincerely searching ahead to developing mutual helpful small business marriage with you!
We take “customer-friendly, quality-oriented, integrative, innovative” as objectives. “Truth and honesty” is our administration ideal for China 4p MCCB and 63A MCCB, You can always find the solutions you have to have in our company! Welcome to inquire us about our product and anything we know and we can help in auto spare parts. We have been looking forward to work with you for a win-win situation.

Product Introduction

RDM5 series moulded case circuit breaker is applied to the circuit of AC 50HZ, insulation voltage 1000V, rated working voltage up to 690V, rated current up to 800A,which to distribute the power and protect the circuit and power source against overload , short-circuit and under voltage damage. Especially, when the current is lower 630A, it also can protect the motor. Normally breaker can infrequently invert and starting of motor. The product can be installed vertically and horizontally

Features

1.Panel Modular Disassembly Design

2.Boxed accessory design,easy installation

3.Ultimate Breaking Ability

4.Compact Size

5.The rated short-circuit breaking current Ics is 10ka higher than the traditional product RDM1′s highest breaking capacity

6.RDM5 durable service life

Company Culture

Enterprise Purpose
Administer enterprises according to law, cooperate in good faith, strive for perfection, be pragmatic, pioneer and innovate

Enterprise Environmental Concept
Go with Green

Enterprise Spirit
Realistic and innovative pursuit of excellence

Enterprise Style
Down to earth, keep improving, and respond quickly and vigorously

Enterprise Quality Concept
Focus on details and pursue perfection

Marketing Concept
Honesty, trustworthiness, mutual benefit and win-winWe take “customer-friendly, quality-oriented, integrative, innovative” as objectives. “Truth and honesty” is our administration ideal for Discount Price Professional Moulded Case Circuit Breaker Manufacturer AC DC 16- 160AMP Low Voltage Protector RCCB/RCBO/ELCB/MCB/MCCB, We’ll do our greatest to fulfill your specifications and are sincerely searching ahead to developing mutual helpful small business marriage with you!
Discount Price China 4p MCCB and 63A MCCB, You can always find the solutions you have to have in our company! Welcome to inquire us about our product and anything we know and we can help in auto spare parts. We have been looking forward to work with you for a win-win situation.

Paraphrase
1 Trademark
2 Product model
3 Technical Parameters
4 Standard
5 CCC Certification mark
6 Company Name
7 Handle
8 Terminal screw
9 Trip button
10 Cover
11 Middle cover
12 Accessory mounting holes
13 Base
17

Upper
Casing

 

 

 

Middle
Piece

 

 

 

Lower
Casing

 

 

18

The product adopts double-layer insulationdesign to improve the safety of users.

19
20
Rated limit short-circuit breaking Icu up to 100ka, suitable for a variety of electrical places
21
22

· 6kA breaking capacity is needed during bidding and tendering,
4.5kA cannot meet the requirements of times any more
· All-series consistent 6kA breaking capacity, more excellent performance
· Meet the customers’ requirement for 50A and 63A breaking capacity
· Power consumption is far below the national standard requirement

23

63/100/125type

>Standard Cabinet: Greatsafety distance                                                   >Non-standard Cabinet: Saving oncabinet cost

24

The rated short-circuit breaking

current Ics is 10ka higher than the

traditional product RDM1′s highest

breakingcapacity, which effectively

improves the product

safetyperformance and meets the

high demand of customers.

25

26

Frame grade rated current l nm(A) 63 125 160 250 400 630 800
Rated currentln(A) 10、16、20、25、32、40、50、63 10、16、20、25、32、40、50、63、80、100、125 63、80、100、125、160 100、125、160、180、200、225、250 200、225、250、315、350、400 400、500、630 630、700、800
Pole(P) 2、3、4 3、4/2、3、4/3、4 3、4/2、3、4 3、4/2、3、4/3、4 3、4
Rated frequency(Hz) 50
Rated insulation voltageUi(V) AC1000
Rated impulse withstand voltage(V) 12000
Rated working voltageUe(V) 400V AC400/AC690
Arcing distance(mm) ≤50 ≤50 ≤50 ≤50 ≤100 ≤100 ≤100
Short-circuit breaking capacity L M S L M H S L M S L M H L M H S L M H L M H
Rated Limit/Rated breaking capacity lcu/lcs(AC400V) 25/15 35/25 25/18 50/35 70/50 100/70 25/18 35/23 50/35 25/18 50/35 70/50 100/70 50/50 70/70 100/75 50/35 50/50 70/70 100/75 65/65 75/75 100/75
Rated Limit/Rated breaking capacity lcu/lcs(AC690V) / / / 20/10. 20/12. 30/15. / 10/5. 15/8. / 20/10. 20/12. 30/15 20/10. 25/15 35/18 / 20/10. 25/15 35/18 20/10. 25/15 35/20
Use category A
Standards compliant IEC60947-2   GB/T14048-2
Suitable for working environment temperature -5℃+40℃
Electrical life(times) 8000 7500
Mechanical life(times) 20000 20000 20000 20000 10000 10000 10000
Shunt release
Undervoltage release
Alarm contact
Auxiliary contact

8

Shape and installation dimensions

27                                           28

 

                              2 poles                                                                                                                3 poles

30                                       31

 

                                        4 poles                                                                                                       Side

Product model Pole Front panel wiring Installation size Button position
L1 L2 L3 L4 L5 L6 W1 W2 W3 H1 H2 H3 H4 H5 H6 K a b d L7 L8
RDM5-63L/M
RDM5-125S/L
2 130.0 - 116.5 85.0 - 49.5 50.0 11.0 25.0 83.0 71.0 - 57.0 24.5 24.5 18.5 - 111.0 3.5 17.0 20.0
3 130.0 - 116.5 85.0 - 49.5 75.0 11.0 50.0 83.0 71.0 - 57.0 24.5 24.5 18.5 25.0 111.0 3.5 16.5 20.0
4 130.0 - 116.5 85.0 - 49.5 100.0 11.0 75.0 83.0 71.0 - 57.0 24.5 24.5 18.5 50.0 111.0 3.5 16.5 20.0
RDM5-125M/H 2 152.0 - 132.0 88.0 31.0 52.0  62 14.5 30.0 109.5 96.0 - 82.0 28.5 28.5 18.0 - 129.0 4.5 - 6.5
3 152.0 - 132.0 88.0 31.0 52.0  92 14.5 60.0 110.0 96.0 - 82.0 28.5 28.5 18.0 30.0 129.0 4.5 22.0 15.5
4 152.0 - 132.0 88.0 31.0 65.0 122.0 14.5 90.0 110.0 96.0 - 82.0 28.5 28.5 18.0 60.0 129.0 4.5 22.0 16.5
RDM5-160S/L/M 2 150.0 - 133.0 88.0 31.0 52.0  62 14.5 30.0 93.0 79.0 - 65.0 23.5 23.5 22.0 - 129.0 3.5 - 16.5
3 150.0 - 133.0 88.0 31.0 52.0  92 14.5 60.0 93.0 79.0 - 65.0 23.5 23.5 22.0 30.0 129.0 3.5 22.0 15.5
4 150.0 - 133.0 88.0 31.0 52.0 122.0 14.5 90.0 93.0 79.0 - 65.0 23.5 23.5 22.0 60.0 129.0 3.5 22.0 16.5
RDM5-250S/L 2 165.0 - 145.5 102.0 33.0 53.0 75.0 14.0 35.0 96.0 76.0 - 67.0  23 23.0 25.0 - 126.0 4.5 2.5 15.5
3 165.0 - 145.5 102.0 33.0 53.0 107.0 14.0 70.0 96.0 76.0 - 67.0  23 23.0 25.0 35.0 126.0 4.5 42.5 5.5
4 165.0 - 145.5 102.0 33.0 53.0 142.0 14.0 105.0 96.0 76.0 - 67.0  23 23.0 25.0 70.0 126.0 4.5 43.0 15.5
RDM5-250M/H 2 165.0 - 145.0 102.0 53.0 53.0 75.0 14.0 55.0 112.5 94.0 - 85.0  22 22.0 24.0 - 126.0 4.5 2.5 15.5
3 165.0 - 145.0 102.0 33.0 53.0 107.0 14.0 70.0 115.0 94.0 - 85.0  23 23.0 23.0 35.0 126.0 4.5 42.5 15.5
4 165.0 - 145.0 102.0 33.0 53.0 142.0 14.0 105.0 115.0 94.0 - 85.0  23 23.0 23.0 70.0 126.0 4.5 43.0 15.0
RDM5-400L/M/H
RDM5-630S
3 258.0 178.0 224.0 132.0 53.0 100.0 150.0 35.0 96.0 152.0 115.0 101.0 99.0  38 38.0 31.0 44.0 194.0 7.0 57.5 30.0
4 258.0 179.0 224.0 132.0 53.0 100.0 198.0 35.0 144.0 152.0 115.0 101.0 99.0  38 38.0 31.0 94.0 194.0 7.0 57.5 30.0
RDM5-630L/M/H 3 270.0 185.0 235.5 146.0 52.5 100.0 182.0 35.5 116.0 158.0 119.0 106.0 103.0  45 43.0 41.0 58.0 200.0 7.0 58.0 32.0
4 270.0 185.0 235.5 146.0 52.5 100.0 240.0 35.5 174.0 158.0 119.0 106.0 103.0  45 43.0 41.0 116.0 200.0 7.0 58.0 31.5
RDM5-800L/M/H 3 280.0 205.0 243.0 148.0 52.0 100.0 210.0 35.0 140.0 159.0 122.0 109.0 105.0 40.5 42.5 45.0 70.0 243.0 7.0 53.0 24.5
4 280.0 205.0 243.0 148.0 52.0 100.0 280.0 35.0 210.0 159.0 122.0 109.0 105.0 40.5 42.5 45.0 140.0 243.0 7.0 53.0 24.5

32

  Size code
(L11) W3 L9   L10
  RDM5-63L M
  RDM5-125S、L
  64 19 14    43
  RDM5-125M H
  RDM5-160S、L M
- 23 24    40
  RDM5-250S.L.M.H - 23 30    44
  RDM5-400L、M、H
  RDM5-630S
- 47 39    66
  RDM5-630L、M、H - 47 39    66
  RDM5-800L、M、H - 47 42    66

RDM5 series rear panel wiring installation panel opening size

33                                                            34

 

                              3 Poles                                                                                                                                    4 Poles

RDM5 series rear panel wiring appearance and installation dimensions

35                                                                         36

 

           RDM5- 125M/H 160、250                                                                                                        RDM5-400、630、800

RDM5-125~800 rear wiring appearance and mounting plate opening size

Product model Size code
H3 H4 D W L2 d2 A B C d1
RDM5-125M H 64 100 M8 50 132 24 30 108 60 5.5
RDM5-160L.M
RDM5-250L、M、H 70 100 M10 35 145 15 35 126 70 5.5
RDM5-400L.M、H
RDM5-630S
71 105.5 - 48 2242 32 44 194 94 7
RDM5-630L.M、H 46 105 - 58 2346 37 58 200 116 7
RDM5-800L,M.H 105 105 - 70 2436 48 70 243 70 7.5

RDM5 series plug-in front panel dimensions

37                                                                               38

 

Flat mount

Dimensions of RDM5-125~800 plug-in front panel circuit breaker

Product model Size code
A G K H H        ₂ Hs L1    L2 AM BM
RDM5-125M H 172 95 38.5 50.5 35   16.5 61 185   217 M6 M8
RDM5-160L,M
RDM5-250L,M、H 183 95 44 52 35   18 65 230   259 M6 M10
RDM5-400L,M,H
RDM5-630S
276 170 53 79.5 67   18 - 322   352 M6 M10
RDM5-630L,M、H 299 163.5 67.5 84.5 65.5   20 - 368   397 M8 M12
RDM5-80OL,M,H 303 179 62 87.5 60.5   28 118 375   405 M10 M12

Hole size of the plug-in front wiring mounting plate (X-XY-Y is the center of the circuit breaker)

40                                                                                     41

 

     Beam installation                                                                                                                Flat mount

RDM5-125~800 plug-in front wiring mounting plate opening size

Product model RDM5-125M.H
RDM5-160L.M
RDM5-250L.M,H RDM5-400L,M,H
RDM5-630S
RDM5-630L,M,H RDM5-800L,M.H
pole 3 3 3 3 3
Mounting plate opening size(mm) B 66 70 115 90.5 90.5
B1 50 60 - - 65
C 60 64 135 144.5 144.5
C1 35 35 - - 80
d 6.5 6.5 6.5 8.5 11

RDM5 series plug-in panel rear dimensions and mounting panel opening dimensions

42                                                                               43

 

Dimensions of RDM5-125~800 plug-in rear panel circuit breaker

Product model Size code
A F G K H H1 H2    H3 H4 AM    BM
RDM5-125M H
RDM5-160L M
168 133 92 38    48 32.5 32.5    18 17 M6    M8
RDM5-25OL、M、H 186 144 95 45.5 49.5 33.5 34    15 17 M6    M8
RDM5-400L、M、H
RDM5-630S
280 224 171 54.5 59.5 40 44  23.5 20 M8   M12
RDM5-630L、M、H 300 234 170 65    59 40 50    30 20 M8   M12
RDM5-800L、M、H 305 243 181 62    87 60 - - 28 M10   M14

Hole size of plug-in rear wiring installation panel (X-XY-Y is the center of the circuit breaker)

44

RDM5-125~800 plug-in rear wiring installation panel opening size

Product model RDM5-125M.H
RDMS-160L.M
RDM5-25OL,M,H   RDM5-400L、M、H
  RDM5-630S
RDM5-630L  M.H RDM5-80OL. M.H
pole 3 4 3 4    3    4 3 4 3 4
Mounting plate opening size(mm) A 91 - 107 -   149 - 182 - 210 -
A1 - 129 - 145 -   200 - 242 - 290
B 60 - 70 -   60 - 100 - 90 -
B1 - 90 - 105 -   108 - 158 - 162
C 56 54 129 123 146
D 38 45.5 54.5 65 62
E 92 95 171 170 181
d 6.5 6.5 8.5 8.5 11
Paraphrase
1 Trademark
2 Product model
3 Technical Parameters
4 Standard
5 CCC Certification mark
6 Company Name
7 Handle
8 Terminal screw
9 Trip button
10 Cover
11 Middle cover
12 Accessory mounting holes
13 Base
17

Upper
Casing

 

 

 

Middle
Piece

 

 

 

Lower
Casing

 

 

18

The product adopts double-layer insulationdesign to improve the safety of users.

19
20
Rated limit short-circuit breaking Icu up to 100ka, suitable for a variety of electrical places
21
22

· 6kA breaking capacity is needed during bidding and tendering,
4.5kA cannot meet the requirements of times any more
· All-series consistent 6kA breaking capacity, more excellent performance
· Meet the customers’ requirement for 50A and 63A breaking capacity
· Power consumption is far below the national standard requirement

23

63/100/125type

>Standard Cabinet: Greatsafety distance                                                   >Non-standard Cabinet: Saving oncabinet cost

24

The rated short-circuit breaking

current Ics is 10ka higher than the

traditional product RDM1′s highest

breakingcapacity, which effectively

improves the product

safetyperformance and meets the

high demand of customers.

25

26

Frame grade rated current l nm(A) 63 125 160 250 400 630 800
Rated currentln(A) 10、16、20、25、32、40、50、63 10、16、20、25、32、40、50、63、80、100、125 63、80、100、125、160 100、125、160、180、200、225、250 200、225、250、315、350、400 400、500、630 630、700、800
Pole(P) 2、3、4 3、4/2、3、4/3、4 3、4/2、3、4 3、4/2、3、4/3、4 3、4
Rated frequency(Hz) 50
Rated insulation voltageUi(V) AC1000
Rated impulse withstand voltage(V) 12000
Rated working voltageUe(V) 400V AC400/AC690
Arcing distance(mm) ≤50 ≤50 ≤50 ≤50 ≤100 ≤100 ≤100
Short-circuit breaking capacity L M S L M H S L M S L M H L M H S L M H L M H
Rated Limit/Rated breaking capacity lcu/lcs(AC400V) 25/15 35/25 25/18 50/35 70/50 100/70 25/18 35/23 50/35 25/18 50/35 70/50 100/70 50/50 70/70 100/75 50/35 50/50 70/70 100/75 65/65 75/75 100/75
Rated Limit/Rated breaking capacity lcu/lcs(AC690V) / / / 20/10. 20/12. 30/15. / 10/5. 15/8. / 20/10. 20/12. 30/15 20/10. 25/15 35/18 / 20/10. 25/15 35/18 20/10. 25/15 35/20
Use category A
Standards compliant IEC60947-2   GB/T14048-2
Suitable for working environment temperature -5℃+40℃
Electrical life(times) 8000 7500
Mechanical life(times) 20000 20000 20000 20000 10000 10000 10000
Shunt release
Undervoltage release
Alarm contact
Auxiliary contact

8

Shape and installation dimensions

27                                           28

 

                              2 poles                                                                                                                3 poles

30                                       31

 

                                        4 poles                                                                                                       Side

Product model Pole Front panel wiring Installation size Button position
L1 L2 L3 L4 L5 L6 W1 W2 W3 H1 H2 H3 H4 H5 H6 K a b d L7 L8
RDM5-63L/M
RDM5-125S/L
2 130.0 - 116.5 85.0 - 49.5 50.0 11.0 25.0 83.0 71.0 - 57.0 24.5 24.5 18.5 - 111.0 3.5 17.0 20.0
3 130.0 - 116.5 85.0 - 49.5 75.0 11.0 50.0 83.0 71.0 - 57.0 24.5 24.5 18.5 25.0 111.0 3.5 16.5 20.0
4 130.0 - 116.5 85.0 - 49.5 100.0 11.0 75.0 83.0 71.0 - 57.0 24.5 24.5 18.5 50.0 111.0 3.5 16.5 20.0
RDM5-125M/H 2 152.0 - 132.0 88.0 31.0 52.0  62 14.5 30.0 109.5 96.0 - 82.0 28.5 28.5 18.0 - 129.0 4.5 - 6.5
3 152.0 - 132.0 88.0 31.0 52.0  92 14.5 60.0 110.0 96.0 - 82.0 28.5 28.5 18.0 30.0 129.0 4.5 22.0 15.5
4 152.0 - 132.0 88.0 31.0 65.0 122.0 14.5 90.0 110.0 96.0 - 82.0 28.5 28.5 18.0 60.0 129.0 4.5 22.0 16.5
RDM5-160S/L/M 2 150.0 - 133.0 88.0 31.0 52.0  62 14.5 30.0 93.0 79.0 - 65.0 23.5 23.5 22.0 - 129.0 3.5 - 16.5
3 150.0 - 133.0 88.0 31.0 52.0  92 14.5 60.0 93.0 79.0 - 65.0 23.5 23.5 22.0 30.0 129.0 3.5 22.0 15.5
4 150.0 - 133.0 88.0 31.0 52.0 122.0 14.5 90.0 93.0 79.0 - 65.0 23.5 23.5 22.0 60.0 129.0 3.5 22.0 16.5
RDM5-250S/L 2 165.0 - 145.5 102.0 33.0 53.0 75.0 14.0 35.0 96.0 76.0 - 67.0  23 23.0 25.0 - 126.0 4.5 2.5 15.5
3 165.0 - 145.5 102.0 33.0 53.0 107.0 14.0 70.0 96.0 76.0 - 67.0  23 23.0 25.0 35.0 126.0 4.5 42.5 5.5
4 165.0 - 145.5 102.0 33.0 53.0 142.0 14.0 105.0 96.0 76.0 - 67.0  23 23.0 25.0 70.0 126.0 4.5 43.0 15.5
RDM5-250M/H 2 165.0 - 145.0 102.0 53.0 53.0 75.0 14.0 55.0 112.5 94.0 - 85.0  22 22.0 24.0 - 126.0 4.5 2.5 15.5
3 165.0 - 145.0 102.0 33.0 53.0 107.0 14.0 70.0 115.0 94.0 - 85.0  23 23.0 23.0 35.0 126.0 4.5 42.5 15.5
4 165.0 - 145.0 102.0 33.0 53.0 142.0 14.0 105.0 115.0 94.0 - 85.0  23 23.0 23.0 70.0 126.0 4.5 43.0 15.0
RDM5-400L/M/H
RDM5-630S
3 258.0 178.0 224.0 132.0 53.0 100.0 150.0 35.0 96.0 152.0 115.0 101.0 99.0  38 38.0 31.0 44.0 194.0 7.0 57.5 30.0
4 258.0 179.0 224.0 132.0 53.0 100.0 198.0 35.0 144.0 152.0 115.0 101.0 99.0  38 38.0 31.0 94.0 194.0 7.0 57.5 30.0
RDM5-630L/M/H 3 270.0 185.0 235.5 146.0 52.5 100.0 182.0 35.5 116.0 158.0 119.0 106.0 103.0  45 43.0 41.0 58.0 200.0 7.0 58.0 32.0
4 270.0 185.0 235.5 146.0 52.5 100.0 240.0 35.5 174.0 158.0 119.0 106.0 103.0  45 43.0 41.0 116.0 200.0 7.0 58.0 31.5
RDM5-800L/M/H 3 280.0 205.0 243.0 148.0 52.0 100.0 210.0 35.0 140.0 159.0 122.0 109.0 105.0 40.5 42.5 45.0 70.0 243.0 7.0 53.0 24.5
4 280.0 205.0 243.0 148.0 52.0 100.0 280.0 35.0 210.0 159.0 122.0 109.0 105.0 40.5 42.5 45.0 140.0 243.0 7.0 53.0 24.5

32

  Size code
(L11) W3 L9   L10
  RDM5-63L M
  RDM5-125S、L
  64 19 14    43
  RDM5-125M H
  RDM5-160S、L M
- 23 24    40
  RDM5-250S.L.M.H - 23 30    44
  RDM5-400L、M、H
  RDM5-630S
- 47 39    66
  RDM5-630L、M、H - 47 39    66
  RDM5-800L、M、H - 47 42    66

RDM5 series rear panel wiring installation panel opening size

33                                                            34

 

                              3 Poles                                                                                                                                    4 Poles

RDM5 series rear panel wiring appearance and installation dimensions

35                                                                         36

 

           RDM5- 125M/H 160、250                                                                                                        RDM5-400、630、800

RDM5-125~800 rear wiring appearance and mounting plate opening size

Product model Size code
H3 H4 D W L2 d2 A B C d1
RDM5-125M H 64 100 M8 50 132 24 30 108 60 5.5
RDM5-160L.M
RDM5-250L、M、H 70 100 M10 35 145 15 35 126 70 5.5
RDM5-400L.M、H
RDM5-630S
71 105.5 - 48 2242 32 44 194 94 7
RDM5-630L.M、H 46 105 - 58 2346 37 58 200 116 7
RDM5-800L,M.H 105 105 - 70 2436 48 70 243 70 7.5

RDM5 series plug-in front panel dimensions

37                                                                               38

 

Flat mount

Dimensions of RDM5-125~800 plug-in front panel circuit breaker

Product model Size code
A G K H H        ₂ Hs L1    L2 AM BM
RDM5-125M H 172 95 38.5 50.5 35   16.5 61 185   217 M6 M8
RDM5-160L,M
RDM5-250L,M、H 183 95 44 52 35   18 65 230   259 M6 M10
RDM5-400L,M,H
RDM5-630S
276 170 53 79.5 67   18 - 322   352 M6 M10
RDM5-630L,M、H 299 163.5 67.5 84.5 65.5   20 - 368   397 M8 M12
RDM5-80OL,M,H 303 179 62 87.5 60.5   28 118 375   405 M10 M12

Hole size of the plug-in front wiring mounting plate (X-XY-Y is the center of the circuit breaker)

40                                                                                     41

 

     Beam installation                                                                                                                Flat mount

RDM5-125~800 plug-in front wiring mounting plate opening size

Product model RDM5-125M.H
RDM5-160L.M
RDM5-250L.M,H RDM5-400L,M,H
RDM5-630S
RDM5-630L,M,H RDM5-800L,M.H
pole 3 3 3 3 3
Mounting plate opening size(mm) B 66 70 115 90.5 90.5
B1 50 60 - - 65
C 60 64 135 144.5 144.5
C1 35 35 - - 80
d 6.5 6.5 6.5 8.5 11

RDM5 series plug-in panel rear dimensions and mounting panel opening dimensions

42                                                                               43

 

Dimensions of RDM5-125~800 plug-in rear panel circuit breaker

Product model Size code
A F G K H H1 H2    H3 H4 AM    BM
RDM5-125M H
RDM5-160L M
168 133 92 38    48 32.5 32.5    18 17 M6    M8
RDM5-25OL、M、H 186 144 95 45.5 49.5 33.5 34    15 17 M6    M8
RDM5-400L、M、H
RDM5-630S
280 224 171 54.5 59.5 40 44  23.5 20 M8   M12
RDM5-630L、M、H 300 234 170 65    59 40 50    30 20 M8   M12
RDM5-800L、M、H 305 243 181 62    87 60 - - 28 M10   M14

Hole size of plug-in rear wiring installation panel (X-XY-Y is the center of the circuit breaker)

44

RDM5-125~800 plug-in rear wiring installation panel opening size

Product model RDM5-125M.H
RDMS-160L.M
RDM5-25OL,M,H   RDM5-400L、M、H
  RDM5-630S
RDM5-630L  M.H RDM5-80OL. M.H
pole 3 4 3 4    3    4 3 4 3 4
Mounting plate opening size(mm) A 91 - 107 -   149 - 182 - 210 -
A1 - 129 - 145 -   200 - 242 - 290
B 60 - 70 -   60 - 100 - 90 -
B1 - 90 - 105 -   108 - 158 - 162
C 56 54 129 123 146
D 38 45.5 54.5 65 62
E 92 95 171 170 181
d 6.5 6.5 8.5 8.5 11
  • Write your message here and send it to us